Clinical application of a novel endoscopic mask: a randomized controlled, multi-center trial in patients undergoing awake fiberoptic bronchoscopic intubation.

BMC Anesthesiology 2017 June 16
BACKGROUND: Awake fiberoptic bronchoscopic tracheal intubation is usually regarded as an effective method in the management of predicted difficult airway. Hypoxia during awake nasal fiberoptic bronchoscopic intubation leads to discontinuation of the procedure, prolonged manipulation time and increased risk of severe complications. The main aim of the study was to test whether the novel endoscopic mask is helpful for hypoxia during the intubation.

METHODS: This was a randomized, controlled, multi-center study. 55 patients were recruited, but one patient was lost to follow-up. Finally, 54 patients (19 man and 35 women) were analyzed. After entering the operating room, nasal catheter oxygen-providing was given in the control group, and the treatment group received endoscopic mask oxygen-providing, with a flow rate of 3 L/min, lasting into the end of the intubation. Primary outcomes included mean arterial pressure, heart rate, minimum pulse oxygen saturation and incidence of pulse oxygen saturation ≤ 90%. Secondary outcomes included number of intubation attempts and time to intubation. All outcomes were finally measured.

RESULTS: Minimum pulse oxygen saturation during awake nasal fiberoptic bronchoscopic tracheal intubation was significantly higher in the endoscopic mask intubation group (91.7% ± 4.7%) than that the nasal catheter intubation group (87.6% ± 8.2%, P = 0.031. Furthermore, the incidence of pulse oxygen saturation ≤ 90% was significantly lower in the endoscopic mask intubation group (20.0%, 5/25) than that in the nasal catheter intubation group (51.7%, 15/29, P = 0.037). But mean arterial pressure of during intubation was significantly higher in the endoscopic mask group (100.0 ± 13.3 vs 90.3 ± 21.8, P = 0.049). In addition, there were no differences in the number of intubation attempts (P = 0.45) or time to intubation between the two groups (P = 0.38).

CONCLUSIONS: The endoscopic mask was safely used in awake fiberoptic bronchoscopic tracheal intubation, with advantages of stable blood pressure and potential prevention of desaturation. Beginners for the intubation procedure and patients at high risk of hypoxia could benefit from the use of the endoscopic mask.

TRIAL REGISTRATION: Trial registration: www.chictr.org.cn . Registration No.: ChiCTR-TRC-13004086. Date of Registration: 8th, Sep, 2013.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app