Comparison of citrated and fresh whole blood for viscoelastic coagulation testing during elective neurosurgery.
Thrombosis Research 2017 August
BACKGROUND: Previous viscoelastic haemostatic tests studies have often indicated a hypercoagulative test signal with citrated blood, which could influence clinical decision makings.
PURPOSE: The aim of this study was to compare fresh and citrated whole blood using two non-automated viscoelastic ROTEM and Sonoclot tests. Our hypothesis was that citrated blood would demonstrate a hypercoagulative response in this setting, not tested before.
METHODS: Perioperative viscoelastic coagulation changes were evaluated with a ROTEM and Sonoclot in 38 patients undergoing elective brain tumor surgery. The citrated samples were recalcified with CaCl2 . Wilcoxon nonparametric-paired tests and Bland-Altman plots were performed to compare the fresh and citrated blood analyses.
RESULTS: The citrated blood showed a hypercoagulative response in ROTEM NATEM-clot formation time and α-angle, Sonoclot-clot rate and platelet function, as compared to fresh blood (p<0.0001).
CONCLUSIONS: Fresh whole blood may theoretically reflect in vivo haemostasis more closely than citrated analyses, which indicated a hypercoagulative response as compared to the fresh whole blood analyses Bland-Altman plots also indicated that ROTEM reference ranges in patients undergoing brain surgery should be redefined. Future studies must establish the correlation between viscoelastic test results using fresh or citrate anticoagulated blood and clinical outcomes, such as bleeding, transfusion or reoperation for postoperative haematoma.
PURPOSE: The aim of this study was to compare fresh and citrated whole blood using two non-automated viscoelastic ROTEM and Sonoclot tests. Our hypothesis was that citrated blood would demonstrate a hypercoagulative response in this setting, not tested before.
METHODS: Perioperative viscoelastic coagulation changes were evaluated with a ROTEM and Sonoclot in 38 patients undergoing elective brain tumor surgery. The citrated samples were recalcified with CaCl2 . Wilcoxon nonparametric-paired tests and Bland-Altman plots were performed to compare the fresh and citrated blood analyses.
RESULTS: The citrated blood showed a hypercoagulative response in ROTEM NATEM-clot formation time and α-angle, Sonoclot-clot rate and platelet function, as compared to fresh blood (p<0.0001).
CONCLUSIONS: Fresh whole blood may theoretically reflect in vivo haemostasis more closely than citrated analyses, which indicated a hypercoagulative response as compared to the fresh whole blood analyses Bland-Altman plots also indicated that ROTEM reference ranges in patients undergoing brain surgery should be redefined. Future studies must establish the correlation between viscoelastic test results using fresh or citrate anticoagulated blood and clinical outcomes, such as bleeding, transfusion or reoperation for postoperative haematoma.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app