We have located links that may give you full text access.
Journal Article
Observational Study
Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients.
Journal of Critical Care 2017 October
PURPOSE: Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients.
METHODS: Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified.
RESULTS: Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%).
CONCLUSION: IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients.
METHODS: Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified.
RESULTS: Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%).
CONCLUSION: IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app