JOURNAL ARTICLE
OBSERVATIONAL STUDY
Add like
Add dislike
Add to saved papers

Coronary CT angiography in the emergency department utilizing second and third generation dual source CT.

BACKGROUND: Coronary computed tomography angiography (coronary CTA) allows efficient triage of low to intermediate risk patients with suspected acute coronary syndrome (ACS) in the emergency department (ED). Techniques for coronary CTA acquisition in the ED continue to evolve with the establishment of standardized scan protocols and the introduction of newer generations of CT hardware.

OBJECTIVES: To evaluate qualitative and quantitative image quality and radiation dose exposure of coronary CTA acquired on 2nd versus 3rd generation dual source CT (DSCT) scanners using a standardized institutional scan protocol designed for the ED.

METHODS: A retrospective observational case-control study was performed of 246 ED patients referred to coronary CTA with suspicion of ACS (56.5% male; mean age 53.3 ± 11.6 years) between October 2013 and August 2015.123 consecutive patients were scanned on 3rd generation DSCT, and a cohort of 123 patients matched by age, BMI and heart rate were identified who had undergone 2nd generation DSCT imaging utilizing the same standard clinical protocol. Qualitative and quantitative image quality parameters and radiation exposures were evaluated.

RESULTS: Qualitative image quality was significantly higher using 3rd generation DSCT as compared to 2nd generation (p < 0.001). Mean attenuation in the proximal coronary arteries was also significantly higher on 3rd generation DSCT than for 2nd generation (586 HU vs. 426 HU in the left main coronary artery (LM), p < 0.001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values, however, were lower in 3rd generation DSCT than 2nd generation (SNR 11.2 [9.9-13.4] vs 13.5 [11.0-15.5] and CNR 12.4 [10.9-14.8] vs 15.2 [12.8-17.9] in the LM, p < 0.001). Median effective dose was also lower for 3rd generation DSCT than for 2nd generation (2.9 [2.3-5.0] mSv and 3.7 mSv [2.5-5.7], respectively) although this trend did not reach statistical significance (p = 0.065).

CONCLUSION: Qualitative image quality and mean CT attenuation values of the assessed coronary segments were significantly higher using 3rd generation DSCT. SNR and CNR were lower on 3rd generation DSCT, however this was accompanied by a trend toward lower radiation dose exposure when using the same standard institutional protocol.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app