Add like
Add dislike
Add to saved papers

Improving the accuracy of microelectrode recording in deep brain stimulation surgery with intraoperative CT.

Microelectrode recording (MER) is used to confirm electrophysiological signals within intended anatomic targets during deep brain stimulation (DBS) surgery. We describe a novel technique called intraoperative CT-guided extrapolation (iCTE) to predict the intended microelectrode trajectory and, if necessary, make corrections in real-time before dural opening. Prior to dural opening, a guide tube was inserted through the headstage and rested on dura. Intraoperative CT (iCT) was obtained, and a trajectory was extrapolated along the path of the guide tube to target depth using targeting software. The coordinates were recorded and compared to initial plan coordinates. If needed, adjustments were made using the headstage to correct for error. The guide tube was then inserted and MER ensued. At target, iCT was performed and microelectrode tip coordinates were compared with planned/adjusted track coordinates. Radial error between MER track and planned/adjusted track was calculated. For comparison, MER track error prior to the iCTE technique was assessed retrospectively in patients who underwent MER using iCT, whereby iCT was performed following completion of the first MER track. Forty-seven MER tracks were analyzed prior to iCTE (pre-iCTE), and 90 tracks were performed using the iCTE technique. There was no difference between radial error of pre-iCTE MER track and planned trajectory (2.1±0.12mm) compared to iCTE predicted trajectory and planned trajectory (1.76±0.13mm, p>0.05). iCTE was used to make trajectory adjustments which reduced radial error between the newly corrected and final microelectrode tip coordinates to 0.84±0.08mm (p<0.001). Inter-rater reliability was also tested using a second blinded measurement reviewer which showed no difference between predicted and planned MER track error (p=0.53). iCTE can predict and reduce trajectory error for microelectrode placement compared with the traditional use of iCT post MER.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app