Value of blood flow velocity on color Doppler ultrasonography for optimization of delay in scanning time on computed tomography venography in patients with Budd-Chiari syndrome and inferior vena cava obstruction.
La Radiologia Medica 2017 June
PURPOSE: To prospectively determine the value of blood flow velocity in the inferior vena cava (IVC) on color Doppler ultrasonography for the optimization of the delay in scanning time after contrast injection during computed tomography (CT) venography in patients with Budd-Chiari syndrome (BCS) with IVC obstruction.
METHODS: We enrolled 122 consecutive BCS patients with IVC obstruction. All patients underwent color Doppler ultrasonography, CT venography, and digital subtraction angiography (DSA) in that order prior to treatment. The delay in scanning time during CT venography was set at 120, 180, 240, and 300 s after contrast injection. The correlation between delay in CT scanning and IVC blood flow velocity on color Doppler ultrasonography was explored. Image quality was classified as good, moderate, or poor. Patients with good CT image quality were considered to have an optimal delay in scanning time.
RESULTS: Delays in scanning time of 120, 180, 240, and 300 s yielded good-quality images in 2, 7, 49, and 64 patients, respectively. The corresponding IVC blood flow velocities in these patients were 16.10 ± 0.42 cm/s (range 15.8-16.4 cm/s), 12.90 ± 1.58 cm/s (range, 11-15 cm/s), 7.53 ± 1.35 cm/s (range 5-10 cm/s), and 1.95 ± 1.75 cm/s (range 0-5.5 cm/s).
CONCLUSION: IVC blood flow velocity on color Doppler ultrasonography could serve as a useful tool for the optimization of the delay in scanning time during CT venography to ensure good-quality images for the diagnosis of BCS with IVC obstruction.
METHODS: We enrolled 122 consecutive BCS patients with IVC obstruction. All patients underwent color Doppler ultrasonography, CT venography, and digital subtraction angiography (DSA) in that order prior to treatment. The delay in scanning time during CT venography was set at 120, 180, 240, and 300 s after contrast injection. The correlation between delay in CT scanning and IVC blood flow velocity on color Doppler ultrasonography was explored. Image quality was classified as good, moderate, or poor. Patients with good CT image quality were considered to have an optimal delay in scanning time.
RESULTS: Delays in scanning time of 120, 180, 240, and 300 s yielded good-quality images in 2, 7, 49, and 64 patients, respectively. The corresponding IVC blood flow velocities in these patients were 16.10 ± 0.42 cm/s (range 15.8-16.4 cm/s), 12.90 ± 1.58 cm/s (range, 11-15 cm/s), 7.53 ± 1.35 cm/s (range 5-10 cm/s), and 1.95 ± 1.75 cm/s (range 0-5.5 cm/s).
CONCLUSION: IVC blood flow velocity on color Doppler ultrasonography could serve as a useful tool for the optimization of the delay in scanning time during CT venography to ensure good-quality images for the diagnosis of BCS with IVC obstruction.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app