Add like
Add dislike
Add to saved papers

Early primary graft failure after a pediatric heart transplant and successful rescue with plasmapheresis, immunoglobulins, and alemtuzumab.

Early primary graft failure after pediatric orthotopic heart transplantation (OHT) has a high mortality rate and can occur due to several causes including but not limited to prolonged graft ischemia time, suboptimal preimplant myocardial preservation, hyperacute rejection, and maladaptation of the graft to the host's hemodynamic status. Mechanical circulatory support with either extracorporeal membrane oxygenation (ECMO) or ventricular assist device has been used for the rescue of primary graft failure in pediatric patients after heart transplant. Cardiac arrest before ECMO initiation in these patients is associated with adverse neurologic outcome although those surviving to hospital discharge generally have excellent long-term outcome. We report a case of early primary graft failure after OHT who required ECMO support and successful rescue with plasmapheresis, immunoglobulins, and alemtuzumab.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app