Development and validation of the Bush-Francis Catatonia Rating Scale - Brazilian version.
Arquivos de Neuro-psiquiatria 2017 January
OBJECTIVE:: This article aims to describe the adaptation and translation process of the Bush-Francis Catatonia Rating Scale (BFCRS) and its reduced version, the Bush-Francis Catatonia Screening Instrument (BFCSI) for Brazilian Portuguese, as well as its validation.
METHODS:: Semantic equivalence processes included four steps: translation, back translation, evaluation of semantic equivalence and a pilot-study. Validation consisted of simultaneous applications of the instrument in Portuguese by two examiners in 30 catatonic and 30 non-catatonic patients.
RESULTS:: Total scores averaged 20.07 for the complete scale and 7.80 for its reduced version among catatonic patients, compared with 0.47 and 0.20 among non-catatonic patients, respectively. Overall values of inter-rater reliability of the instruments were 0.97 for the BFCSI and 0.96 for the BFCRS.
CONCLUSION:: The scale's version in Portuguese proved to be valid and was able to distinguish between catatonic and non-catatonic patients. It was also reliable, with inter-evaluator reliability indexes as high as those of the original instrument.
METHODS:: Semantic equivalence processes included four steps: translation, back translation, evaluation of semantic equivalence and a pilot-study. Validation consisted of simultaneous applications of the instrument in Portuguese by two examiners in 30 catatonic and 30 non-catatonic patients.
RESULTS:: Total scores averaged 20.07 for the complete scale and 7.80 for its reduced version among catatonic patients, compared with 0.47 and 0.20 among non-catatonic patients, respectively. Overall values of inter-rater reliability of the instruments were 0.97 for the BFCSI and 0.96 for the BFCRS.
CONCLUSION:: The scale's version in Portuguese proved to be valid and was able to distinguish between catatonic and non-catatonic patients. It was also reliable, with inter-evaluator reliability indexes as high as those of the original instrument.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app