OBJECTIVE: The etiology of necrotizing enterocolitis (NEC) remains elusive despite known associations with several factors, including intestinal ischemia related to the effects of umbilical arterial catheterization on the mesenteric circulation. However, the role of the mesenteric venous circulation has yet to be studied as a potential cause of NEC. We examined the association between umbilical venous catheter (UVC) position and the development of NEC in premature infants.
DESIGN: A prospective cohort study was performed to examine the effect of UVC on portosystemic shunting via the ductus venosus (DV) and its potential role in NEC.
RESULTS: We recruited 132 premature infants, 62 of which had a birth weight ≤1,500 g. NEC was noted in 12 (19%) patients. All infants weighing ≤1,500 g underwent an attempt at UVC insertion. The UVC status was classified as appropriate (n = 39), unsuccessful (n = 9), or malpositioned (n = 14). Among the NEC patients, 7 (58%) had a UVC malposition and 3 (25%) had an unsuccessful attempt. These rates were significantly higher than in patients without NEC (14 and 12%, respectively). Multivariable logistic regression analysis confirmed birth weight (OR 2.2, 95% CI 1.2-4.7, p = 0.001) and UVC malpositioning (OR 6.9, 95% CI 1.6-35.4, p = 0.007) as independent risk factors associated with NEC.
CONCLUSIONS: Unrecognized withdrawal of a UVC into the portal vein or DV is associated with an increased incidence of NEC in infants weighing ≤1,500 g. The data support the need for additional studies to examine this effect. Confirmation of a causal relationship will raise the need to reassess UVC insertion criteria and strategies for more closely monitoring the catheter tip position.
DESIGN: A prospective cohort study was performed to examine the effect of UVC on portosystemic shunting via the ductus venosus (DV) and its potential role in NEC.
RESULTS: We recruited 132 premature infants, 62 of which had a birth weight ≤1,500 g. NEC was noted in 12 (19%) patients. All infants weighing ≤1,500 g underwent an attempt at UVC insertion. The UVC status was classified as appropriate (n = 39), unsuccessful (n = 9), or malpositioned (n = 14). Among the NEC patients, 7 (58%) had a UVC malposition and 3 (25%) had an unsuccessful attempt. These rates were significantly higher than in patients without NEC (14 and 12%, respectively). Multivariable logistic regression analysis confirmed birth weight (OR 2.2, 95% CI 1.2-4.7, p = 0.001) and UVC malpositioning (OR 6.9, 95% CI 1.6-35.4, p = 0.007) as independent risk factors associated with NEC.
CONCLUSIONS: Unrecognized withdrawal of a UVC into the portal vein or DV is associated with an increased incidence of NEC in infants weighing ≤1,500 g. The data support the need for additional studies to examine this effect. Confirmation of a causal relationship will raise the need to reassess UVC insertion criteria and strategies for more closely monitoring the catheter tip position.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app