We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Evaluation of gum-elastic bougie combined with direct and indirect laryngoscopes in vomitus setting: A randomized simulation trial.
American Journal of Emergency Medicine 2017 April
PURPOSE: Videolaryngoscopes may not be useful in the presence of vomitus due to blurred images on the monitor. The objective of our study is to compare the utility of gum-elastic bougie (GEB) application for tracheal intubation with the Macintosh laryngoscope (McL), which is a direct laryngoscope, with that of the Pentax-AWS Airwayscope® (AWS) and McGRATH® MAC (McGRATH) in simulated vomitus settings.
METHODS: Sixteen novice doctors performed tracheal intubation on an adult manikin using McL, AWS, and McGRATH with or without GEB under normal and vomitus simulations.
RESULTS: In the normal setting the tracheal intubation was successful with the three laryngoscopes regardless of GEB application. In the vomitus setting, the intubation success rate did not significantly improve using McL, while it did using McGRATH or AWS. In the normal settings, GEB application significantly lengthened the intubation time in all three laryngoscopes. By contrast, in the vomitus settings, GEB application significantly shortened the intubation time in all three laryngoscopes. For the comparison of three laryngoscopes, the intubation time did not differ significantly in normal setting, while it was significantly longer in McG and AWS trials than McL trial.
CONCLUSION: The GEB application facilitates the tracheal intubation in the vomitus setting using McGRATH and AWS in adult simulation.
METHODS: Sixteen novice doctors performed tracheal intubation on an adult manikin using McL, AWS, and McGRATH with or without GEB under normal and vomitus simulations.
RESULTS: In the normal setting the tracheal intubation was successful with the three laryngoscopes regardless of GEB application. In the vomitus setting, the intubation success rate did not significantly improve using McL, while it did using McGRATH or AWS. In the normal settings, GEB application significantly lengthened the intubation time in all three laryngoscopes. By contrast, in the vomitus settings, GEB application significantly shortened the intubation time in all three laryngoscopes. For the comparison of three laryngoscopes, the intubation time did not differ significantly in normal setting, while it was significantly longer in McG and AWS trials than McL trial.
CONCLUSION: The GEB application facilitates the tracheal intubation in the vomitus setting using McGRATH and AWS in adult simulation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app