COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Dosimetric characterization of hypofractionated Gamma Knife radiosurgery of large or complex brain tumors versus linear accelerator-based treatments.

OBJECTIVE Noninvasive Gamma Knife (GK) platforms, such as the relocatable frame and on-board imaging, have enabled hypofractionated GK radiosurgery of large or complex brain lesions. This study aimed to characterize the dosimetric quality of such treatments against linear accelerator-based delivery systems that include the CyberKnife (CK) and volumetric modulated arc therapy (VMAT). METHODS Ten patients treated with VMAT at the authors' institution for large brain tumors (> 3 cm in maximum diameter) were selected for the study. The median prescription dose was 25 Gy (range 20-30 Gy) in 5 fractions. The median planning target volume (PTV) was 9.57 cm3 (range 1.94-24.81 cm3 ). Treatment planning was performed using Eclipse External Beam Planning V11 for VMAT on the Varian TrueBeam system, Multiplan V4.5 for the CyberKnife VSI System, and Leksell GammaPlan V10.2 for the Gamma Knife Perfexion system. The percentage of the PTV receiving at least the prescription dose was normalized to be identical across all platforms for individual cases. The prescription isodose value for the PTV, conformity index, Paddick gradient index, mean and maximum doses for organs at risk, and normal brain dose at variable isodose volumes ranging from the 5-Gy isodose volume (V5) to the 15-Gy isodose volume (V15) were compared for all of the cases. RESULTS The mean Paddick gradient index was 2.6 ± 0.2, 3.2 ± 0.5, and 4.3 ± 1.0 for GK, CK, and VMAT, respectively (p < 0.002). The mean V15 was 7.5 ± 3.7 cm3 (range 1.53-13.29 cm3 ), 9.8 ± 5.5 cm3 (range 2.07-18.45 cm3 ), and 16.1 ± 10.6 cm3 (range 3.58-36.53 cm3 ) for GK, CK, and VMAT, respectively (p ≤ 0.03, paired 2-tailed t-tests). However, the average conformity index was 1.18, 1.12, and 1.21 for GK, CK, and VMAT, respectively (p > 0.06). The average prescription isodose values were 52% (range 47%-69%), 60% (range 46%-68%), and 88% (range 70%-94%) for GK, CK, and VMAT, respectively, thus producing significant variations in dose hot spots among the 3 platforms. Furthermore, the mean V5 values for GK and CK were similar (p > 0.79) at 71.9 ± 36.2 cm3 and 73.3 ± 31.8 cm3 , respectively, both of which were statistically lower (p < 0.01) than the mean V5 value of 124.6 ± 67.1 cm3 for VMAT. CONCLUSIONS Significantly better near-target normal brain sparing was noted for hypofractionated GK radiosurgery versus linear accelerator-based treatments. Such a result supports the use of a large number of isocenters or confocal beams for the benefit of normal tissue sparing in hypofractionated brain radiosurgery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app