Add like
Add dislike
Add to saved papers

Computed tomography findings of the bony portion of the Eustachian tube with or without patulous Eustachian tube patients.

To investigate the bony segment of the Eustachian tube (ET) using sitting 3D-computed tomography (CT) scans in Patulous Eustachian tube (PET) patients. A retrospective survey of medical records in Sen-En Hospital identified 43 patients and 43 ears with PET and 30 patients and 30 ears with sensorineural hearing loss or vertigo patients as the control. Diagnosis of PET was based on the Proposal on PET Diagnosis Criteria announced by the Otological Society of Japan in 2012. Patients were examined by cone beam CT (Accuitomo; Morita, Kyoto, Japan) in the sitting position. The heights and widths at the tympanic orifice, the middle portion, and isthmus were measured. The lumen of the bony portion was divided into three shapes: peritubal cells (PTC) poor type, PTC good with prominence type, and PTC good without prominence type. In PET patients and the control group, the PTC poor type was identified in nine (21%) and seven ears (23%), PTC good with prominence type was identified in 14 (33%) and seven ears (23%), and PTC good without prominence type was identified in 19 (45%) and 16 ears (53%), respectively. There was no significant difference between the two groups. At the tympanic orifice portion, the average height of the ET lumen was 5.99 ± 1.29 and 6.04 ± 1.41 mm, and the average width of the ET lumen was 2.81 ± 0.82 and 2.78 ± 0.57 mm in the PET and control groups, respectively. The PTC good with prominence type had a significantly smaller width in the tympanic orifice portion than the other types in each group (p < 0.05). The width of the ET lumen in the tympanic orifice averaged 2.87 ± 0.38 and 3.10 ± 0.45 mm in the PTC poor type, 2.23 ± 0.70 and 2.22 ± 0.48 mm in the PTC good with prominence type, and 3.21 ± 0.87 and 2.90 ± 0.50 mm in the PTC good without prominence type in the PET and control groups, respectively. The shape of the bony portion of the ET in PET patients is almost identical to that of controls. Thus, the bony portion has no influence on the pathology of patulous Eustachian tube syndrome. The PTC good with prominence type has a significantly smaller tympanic orifice portion width than the other types. Preoperative evaluation of the bony portion of the ET could provide useful information for ET surgeons.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app