Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Comparison of three monocular methods for measuring accommodative stimulus-response curves.

PURPOSE: The aim was to evaluate the repeatability of dynamic measurement of the accommodative stimulus-response curve (ASRC) at three different dioptric speeds using a modified instrument and its agreement with two other methods.

METHODS: Twenty-nine adults (23.5 ± 2.0 years) were enrolled in the study. ASRC was measured monocularly using three methods: dynamic and static measurement using a motorised Badal system mounted on an open-field auto-refractor (WAM-5500, Grand Seiko Co., Ltd, Japan) and the minus lens technique. Dynamic measurements were conducted at three dioptric stimulus speeds to simulate continuous stimuli for ASRC (0.25, 0.40 and 0.55 D/s), with three repetitions for each speed. All three types of ASRCs were fitted with third-degree polynomial equations. The slope and objective accommodative amplitude of the ASRC were analysed.

RESULTS: The repeatability of objective accommodative amplitude worsened as the speed of the stimuli increased. The repeatability of the slope was best at a speed of 0.40 D/s and worst at 0.55 D/s. The measurement method significantly influenced the objective accommodative amplitude values and slope (both, p < 0.001). The minus lens technique yielded the highest amplitude of accommodation (6.21 ± 0.84 D) and steepest slope (1.11 ± 0.14), followed by the static Badal method (5.60 ± 0.83 D and 0.89 ± 0.09 D). The objective accommodative amplitude decreased with increasing speed during dynamic measurements. There was no difference between the slopes at 0.25 D and 0.40 D/s (p > 0.05) and the slope was lowest at 0.55 D/s.

CONCLUSION: The accommodative stimulus-response curve values are method-dependent and the significant differences between three methods used to determine the ASRC based on slope and accommodative amplitude indicate that these methods are non-interchangeable. Using dynamic measurements, accommodative behaviour varies with the speed of dioptric-change of the stimulus. A speed of 0.40 D/s appears to be the best compromise in terms of time, results and repeatability for dynamic ASRC measurement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app