We have located links that may give you full text access.
Initial Experience of Robotic Sleeve Resection for Lung Cancer Patients.
Annals of Thoracic Surgery 2016 December
BACKGROUND: The purpose of this study was to identify the technical aspects and short-term results of robotic sleeve resection for lung cancer patients.
METHODS: Twenty-one consecutive cases of robotic sleeve resection from September 2014 to September 2015 were reviewed.
RESULTS: There were 17 single sleeve resection (bronchial) and 4 double sleeve resection (bronchial and vascular) cases. Nineteen of 21 cases (90.5%) achieved R0 resection. The mean console time was 120.4 ± 37.3 minutes. The mean operation time was 158.4 ± 42.0 minutes. There was no massive bleeding (800 mL or more) during operation. The mean intraoperative blood loss was 157.1 ± 97.8 mL. One case (4.8%) was converted to thoracotomy owing to severe calcification of lymph node. There was no intraoperative death. The overall complication rate was 19.0%. The major complications were subcutaneous emphysema (14.4%), cardiac arrhythmia (9.6%), pneumonia (9.6%), pyothorax (9.6%), bronchial anastomosis bleeding (4.8%), bronchial anastomosis leakage (4.8%), and multiple organ failure (4.8%). The 30-day mortality rate was 4.8%. The mean postoperative length of stay was 10.7 ± 7.6 days.
CONCLUSIONS: Robotic sleeve resection is technically feasible and can be carried out with acceptable short-term results.
METHODS: Twenty-one consecutive cases of robotic sleeve resection from September 2014 to September 2015 were reviewed.
RESULTS: There were 17 single sleeve resection (bronchial) and 4 double sleeve resection (bronchial and vascular) cases. Nineteen of 21 cases (90.5%) achieved R0 resection. The mean console time was 120.4 ± 37.3 minutes. The mean operation time was 158.4 ± 42.0 minutes. There was no massive bleeding (800 mL or more) during operation. The mean intraoperative blood loss was 157.1 ± 97.8 mL. One case (4.8%) was converted to thoracotomy owing to severe calcification of lymph node. There was no intraoperative death. The overall complication rate was 19.0%. The major complications were subcutaneous emphysema (14.4%), cardiac arrhythmia (9.6%), pneumonia (9.6%), pyothorax (9.6%), bronchial anastomosis bleeding (4.8%), bronchial anastomosis leakage (4.8%), and multiple organ failure (4.8%). The 30-day mortality rate was 4.8%. The mean postoperative length of stay was 10.7 ± 7.6 days.
CONCLUSIONS: Robotic sleeve resection is technically feasible and can be carried out with acceptable short-term results.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app