Relationship between abnormal P-wave terminal force in lead V1 and left ventricular diastolic dysfunction in hypertensive patients: the LIFE study

Michael T Tanoue, Sverre E Kjeldsen, Richard B Devereux, Peter M Okin
Blood Pressure 2017, 26 (2): 94-101
27601135

BACKGROUND: Abnormal P-wave terminal force in lead V1 (PTF-V1) is an ECG marker of increased left atrial (LA) volume, elevated LA filling pressures and/or LA systolic dysfunction. Because left ventricular (LV) diastolic dysfunction is one of the potential mechanisms driving LA remodelling, we hypothesized that PTF-V1 might be an additional ECG marker of diastolic dysfunction.

METHODS: LV diastolic function after 3 years' systematic antihypertensive treatment was examined in relation to baseline PTF-V1 in 431 hypertensive patients undergoing protocol-driven blood pressure reduction who had baseline and year-3 ECG and echocardiographic data and a preserved LV ejection fraction (EF >45%) at year-3. Abnormal diastolic function was defined by the tenth or 90th percentile values from 405 normotensive, non-obese and non-diabetic adults without overt cardiovascular disease. Abnormal PTF-V1, defined by the presence of a negative terminal P-wave in lead V1 ≥ 4000 μV·ms, was present in 167 patients (38.7%).

RESULTS: Abnormal PTF-V1 was associated with worse year-3 mean diastolic first third filling time (0.43 ± 0.08 vs 0.40 ± 0.07 sec, p = 0.039), first half filling time (0.55 ± 0.07 vs 0.53 ± 0.07 sec, p = 0.041), mitral valve A velocity (86 ± 27 vs 76 ± 19 cm/sec, p = 0.009) and mitral valve E/A ratio (0.85 ± 0.22 vs 0.94 ± 0.27, p = 0.007) after adjusting for other potential predictors of diastolic dysfunction including race, and heart rate, systolic blood pressure and severity of ECG LVH by Cornell product criteria at baseline. In parallel multivariate logistic regression analysis, abnormal PTF-V1 was associated with significantly increased odds of abnormal mitral valve E/A ratio (OR 1.55, 95%CI 1.04-2.32 p = 0.032), and a trend toward higher odds of abnormal half filling time (OR 1.42, 95%CI 0.94-2.15, p = 0.098) at year-3 of follow-up.

CONCLUSIONS: Abnormal P-wave terminal force in lead V1 is associated with worse diastolic function and predicts abnormal LV diastolic behaviour in patients with preserved EF after 3 years of blood pressure reductive therapy.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
27601135
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"