RESEARCH SUPPORT, NON-U.S. GOV'T
Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter.
Journal of Cardiovascular Electrophysiology 2016 December
INTRODUCTION: This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort.
METHODS AND RESULTS: Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF.
CONCLUSION: CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.
METHODS AND RESULTS: Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF.
CONCLUSION: CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app