COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes.

BACKGROUND: In patients with type 1 diabetes who are not pregnant, closed-loop (automated) insulin delivery can provide better glycemic control than sensor-augmented pump therapy, but data are lacking on the efficacy, safety, and feasibility of closed-loop therapy during pregnancy.

METHODS: We performed an open-label, randomized, crossover study comparing overnight closed-loop therapy with sensor-augmented pump therapy, followed by a continuation phase in which the closed-loop system was used day and night. Sixteen pregnant women with type 1 diabetes completed 4 weeks of closed-loop pump therapy (intervention) and sensor-augmented pump therapy (control) in random order. During the continuation phase, 14 of the participants used the closed-loop system day and night until delivery. The primary outcome was the percentage of time that overnight glucose levels were within the target range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]).

RESULTS: The percentage of time that overnight glucose levels were in the target range was higher during closed-loop therapy than during control therapy (74.7% vs. 59.5%; absolute difference, 15.2 percentage points; 95% confidence interval, 6.1 to 24.2; P=0.002). The overnight mean glucose level was lower during closed-loop therapy than during control therapy (119 vs. 133 mg per deciliter [6.6 vs. 7.4 mmol per liter], P=0.009). There were no significant differences between closed-loop and control therapy in the percentage of time in which glucose levels were below the target range (1.3% and 1.9%, respectively; P=0.28), in insulin doses, or in adverse-event rates. During the continuation phase (up to 14.6 additional weeks, including antenatal hospitalizations, labor, and delivery), glucose levels were in the target range 68.7% of the time; the mean glucose level was 126 mg per deciliter (7.0 mmol per liter). No episodes of severe hypoglycemia requiring third-party assistance occurred during either phase.

CONCLUSIONS: Overnight closed-loop therapy resulted in better glucose control than sensor-augmented pump therapy in pregnant women with type 1 diabetes. Women receiving day-and-night closed-loop therapy maintained glycemic control during a high proportion of the time in a period that encompassed antenatal hospital admission, labor, and delivery. (Funded by the National Institute for Health Research and others; Current Controlled Trials number, ISRCTN71510001.).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app