We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Optimization of two-compartment-exchange-model analysis for dynamic contrast-enhanced mri incorporating bolus arrival time.
Journal of Magnetic Resonance Imaging : JMRI 2017 January
PURPOSE: To optimize the analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) under the two-compartment-exchange-model (2CXM) and to incorporate voxelwise bolus-arrival-time (BAT).
MATERIALS AND METHODS: The accuracy of the pharmacokinetic (PK) parameters, extracted from 3T DCE-MRI using 2CXM, was tested under several conditions: eight algorithms for data estimation; correction for BAT; using model selection; different temporal resolution and scan duration. Comparisons were performed on simulated data. The best algorithm was applied to seven patients with brain tumors or following stroke. The extracted perfusion parameters were compared to those of dynamic susceptibility contrast MRI (DSC-MRI).
RESULTS: ACoPeD (AIF-corrected-perfusion-DCE-MRI), an analysis using a 2nd derivative regularized-spline and incorporating BAT, achieved the most accurate estimation in simulated data, mean-relative-error: Fp , F, vp , ve : 24.8%, 41.7%, 26.4%, 27.2% vs. 76.5%, 190.8%, 78.8%, 82.39% of the direct four parameters estimation (one-sided two-sample t-test, P < 0.001). Correction for BAT increased the estimation accuracy of the PK parameters by more than 30% and provided a supertemporal resolution estimation of the BAT (higher than the acquired resolution, mean-absolute-error 0.2 sec). High temporal resolution (∼2 sec) is required to avoid biased estimation of PK parameters, and long scan duration (∼20 min) is important for reliable permeability but not for perfusion estimations, mean-error-reduction: E: ∼12%, ve : ∼6%. Using ACoPeD, PK values from normal-appearing white matter, gray matter, and lesion were extracted from patients. Preliminary results showed significant voxelwise correlations to DSC-MRI, between flow values in a patient following stroke (r = 0.49, P < 0.001), and blood volume in a patient with a brain tumor (r = 0.62, P < 0.001).
CONCLUSION: This study proposes an optimized analysis method, ACoPeD, for tissue perfusion and permeability estimation using DCE-MRI, to be used in clinical settings.
LEVEL OF EVIDENCE: 1 J. Magn. Reson. Imaging 2017;45:237-249.
MATERIALS AND METHODS: The accuracy of the pharmacokinetic (PK) parameters, extracted from 3T DCE-MRI using 2CXM, was tested under several conditions: eight algorithms for data estimation; correction for BAT; using model selection; different temporal resolution and scan duration. Comparisons were performed on simulated data. The best algorithm was applied to seven patients with brain tumors or following stroke. The extracted perfusion parameters were compared to those of dynamic susceptibility contrast MRI (DSC-MRI).
RESULTS: ACoPeD (AIF-corrected-perfusion-DCE-MRI), an analysis using a 2nd derivative regularized-spline and incorporating BAT, achieved the most accurate estimation in simulated data, mean-relative-error: Fp , F, vp , ve : 24.8%, 41.7%, 26.4%, 27.2% vs. 76.5%, 190.8%, 78.8%, 82.39% of the direct four parameters estimation (one-sided two-sample t-test, P < 0.001). Correction for BAT increased the estimation accuracy of the PK parameters by more than 30% and provided a supertemporal resolution estimation of the BAT (higher than the acquired resolution, mean-absolute-error 0.2 sec). High temporal resolution (∼2 sec) is required to avoid biased estimation of PK parameters, and long scan duration (∼20 min) is important for reliable permeability but not for perfusion estimations, mean-error-reduction: E: ∼12%, ve : ∼6%. Using ACoPeD, PK values from normal-appearing white matter, gray matter, and lesion were extracted from patients. Preliminary results showed significant voxelwise correlations to DSC-MRI, between flow values in a patient following stroke (r = 0.49, P < 0.001), and blood volume in a patient with a brain tumor (r = 0.62, P < 0.001).
CONCLUSION: This study proposes an optimized analysis method, ACoPeD, for tissue perfusion and permeability estimation using DCE-MRI, to be used in clinical settings.
LEVEL OF EVIDENCE: 1 J. Magn. Reson. Imaging 2017;45:237-249.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university