Impact of transesophageal echocardiography during transseptal puncture on atrial fibrillation ablation.

BACKGROUND: The aim of our study was to demonstrate the added value of routine transesophageal echocardiography (TEE) for correctly positioning the transseptal system in the fossa ovalis (FO), thus potentially preventing complications during fluoroscopy-guided transseptal puncture (TP), and for assessing the optimal puncture site within the FO according to the expected procedure type.

METHODS: Ninety-one patients undergoing pulmonary vein isolation (PVI) procedures by cryoballoon technique for drug-resistant paroxysmal or persistent atrial fibrillation (AF) were prospectively included. In 57 patients, the TP procedure was performed under fluoroscopic guidance and septal localization was confirmed by contrast injection through the needle and demonstration of septal tenting in both the anteroposterior and left lateral fluoroscopic projections. In 34 patients, TP was performed under TEE guidance and positioning was targeted to perform the TP procedure in the more anterior and inferior locations of the FO. Two patient groups were compared according to the incidence of complications directly attributable to transseptal catheterization, thromboembolic complications, recurrence rates after the ablation procedure, total procedural time, and fluoroscopy time.

RESULTS: Fluoroscopy time (p<0.001), total cryoablation time (p=0.002), and total procedural time (p<0.001) were shorter in the TEE-guided group. Left inferior pulmonary vein (LIPV) cryoablation time (p=0.007) and right inferior pulmonary vein (RIPV) cryoablation time (p=0.004) were significantly shorter and the number of applications to the LIPV (p=0.007) and RIPV (p=0.005) were significantly fewer in the TEE-guided group. Although there was a trend toward higher complication rates (20.6% vs. 31.6%, p=0.37) and recurrence rates (11.8% vs. 20.1%, p=0.26) in the fluoroscopy-guided group, the differences between the groups were not statistically significant.

CONCLUSIONS: TEE-guided TP for AF ablation is associated with shorter fluoroscopy time, shorter total cryoablation time, and shorter total procedural time. Importantly, TEE-guided TP facilitates cryoablation of the inferior pulmonary veins.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app