Detection of LA and LAA Thrombus by CMR in Patients Referred for Pulmonary Vein Isolation.

OBJECTIVES: The goal of this study was to evaluate the diagnostic performance of a comprehensive, multicomponent cardiac magnetic resonance (CMR) study for assessment of left atrial (LA) and left atrial appendage (LAA) thrombus.

BACKGROUND: Pre-operative evaluation for pulmonary vein isolation (PVI) typically requires tomographic imaging to define pulmonary venous anatomy and transesophageal echocardiogram (TEE) to assess for the presence of LA/LAA thrombus. CMR is increasingly being used to define pulmonary venous anatomy before PVI. Limited data are available on the utility of a multicomponent CMR protocol in assessing LA/LAA thrombus.

METHODS: We studied patients who underwent multicomponent CMR for evaluation of pulmonary venous anatomy before PVI and underwent TEE within 7 days. LA and LAA thrombi were evaluated by using CMR as follows: 1) cine-CMR; 2) contrast-enhanced magnetic resonance angiography; and 3) equilibrium phase delayed enhancement (DE) CMR with a long inversion time (TI) of 600 ms (long TI DE-CMR). Components of the CMR study were evaluated for diagnostic performance for detection of LA or LAA thrombus using TEE as the reference standard.

RESULTS: During the study period, 261 patients were assessed. The median CHA2DS2VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65 to 74 years, sex category) score was 2, and 73.6% of patients were undergoing anticoagulation therapy. CMR and TEE were performed within 1.3 ± 2.3 days. LA/LAA thrombi were discovered in 9 patients (3.5%) by using TEE. Among the CMR techniques performed, long TI DE-CMR had the highest diagnostic accuracy (99.2%), sensitivity (100%), and specificity (99.2%), followed by contrast-enhanced magnetic resonance angiography (accuracy 94.3%; sensitivity 66.7%; and specificity 95.2%) and cine-CMR (accuracy 91.6%; sensitivity 66.7%; and specificity 92.5%).

CONCLUSIONS: In patients referred for PVI, CMR could be a single complete diagnostic study for assessment of pulmonary venous anatomy as well as presence of LA/LAA thrombi, thus reducing the number of pre-operative tests before PVI. Long TI DE-CMR has the best diagnostic performance and should be used for the detection of LA/LAA thrombi.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app