We have located links that may give you full text access.
Predictive Value of Exercise Stress Test-Induced ST-Segment Changes in Leads V 1 and avR in Determining Angiographic Coronary Involvement.
Annals of Noninvasive Electrocardiology 2017 January
BACKGROUND: The significance of electrocardiographic changes during exercise tolerance testing for distinguishing occluded artery is not well known. We tried to determine the role of ST elevation in leads aVR and V1 during exercise in detecting stenosis of left main coronary artery and proximal left anterior descending artery.
METHODS: ST segment changes during exercise in 230 patients, who underwent diagnostic angiography, were documented. The association of ST elevation in lead aVR, V1 , leads aVR + V1 , and STE in leads aVR + V1 with ST depression in other leads with pattern of coronary stenosis were investigated.
RESULTS: Left main and proximal left anterior artery stenosis were more common in patients with ST elevation in lead aVR (P < 0.001 for both). Similar association was found in the presence of ST elevation in lead V1 . The presence of ST elevation ≥1 mm in lead aVR had a sensitivity of 100% and 94.3% for detecting left main and left anterior descending artery stenosis, respectively. The specificity was 33.5% and 26.6%, respectively. ST elevation in leads aVR + V1 had a sensitivity of 74.4% and 65.9% and a specificity of 68.5% and 64.4% for detecting left main and left anterior descending arteries stenosis, respectively.
CONCLUSION: ST elevation in lead aVR is highly sensitive for left main and proximal left anterior descending artery lesions. Using ST elevation in lead V1 in addition to lead aVR as a positive finding increases the specificity with a further decrease in sensitivity.
METHODS: ST segment changes during exercise in 230 patients, who underwent diagnostic angiography, were documented. The association of ST elevation in lead aVR, V1 , leads aVR + V1 , and STE in leads aVR + V1 with ST depression in other leads with pattern of coronary stenosis were investigated.
RESULTS: Left main and proximal left anterior artery stenosis were more common in patients with ST elevation in lead aVR (P < 0.001 for both). Similar association was found in the presence of ST elevation in lead V1 . The presence of ST elevation ≥1 mm in lead aVR had a sensitivity of 100% and 94.3% for detecting left main and left anterior descending artery stenosis, respectively. The specificity was 33.5% and 26.6%, respectively. ST elevation in leads aVR + V1 had a sensitivity of 74.4% and 65.9% and a specificity of 68.5% and 64.4% for detecting left main and left anterior descending arteries stenosis, respectively.
CONCLUSION: ST elevation in lead aVR is highly sensitive for left main and proximal left anterior descending artery lesions. Using ST elevation in lead V1 in addition to lead aVR as a positive finding increases the specificity with a further decrease in sensitivity.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app