We have located links that may give you full text access.
Leg lateral reach test: The reliability and correlation with thoraco-lumbo-pelvic rotation range.
Journal of Science and Medicine in Sport 2017 January
OBJECTIVES: The aim of the present study was to examine the intra- and inter-rater reliabilities of the leg lateral reach test as a screening tool for thoraco-lumbo-pelvic rotation and to assess the relationship between leg lateral reach distance and thoraco-lumbo-pelvic rotation range in a supine position.
DESIGN: Controlled laboratory study.
METHODS: Thirty-six physically active participants were recruited. The leg lateral reach test was performed over 2 days. In the first session, two testers measured the distance of the leg lateral reach to determine the within-day inter-rater reliability, and one tester repeated the measurement on day 2 to determine the intra-rater reliability between days. The leg lateral reach test was performed three times per leg, and the mean value was used for data analysis. Reliability was determined using the intraclass correlation coefficient, standard error of measurement, and minimal detectable change. The correlation between leg lateral reach distance and thoraco-lumbo-pelvic rotation range was determined using Pearson correlation.
RESULTS: Almost perfect intra- and inter-rater reliabilities were shown for the test [intraclass correlation coefficient2,3=0.97 (95% confidence interval=0.914-0.984) and 0.99 (0.974-0.996), respectively]. The within-day inter-rater standard error of measurement was 1.40cm, and the minimal detectable change was 3.87cm. The between-day intra-rater standard error of measurement was 2.66cm, and the minimal detectable change was 7.37cm. The Pearson correlation showed a moderate to good correlation between the leg lateral reach distance and the thoraco-lumbo-pelvic rotation range (r=0.73).
CONCLUSIONS: The leg lateral reach screening test is reliable for measuring thoraco-lumbo-pelvic rotation range and allows for practical measurement of the thoraco-lumbo-pelvic rotation range in a supine position.
DESIGN: Controlled laboratory study.
METHODS: Thirty-six physically active participants were recruited. The leg lateral reach test was performed over 2 days. In the first session, two testers measured the distance of the leg lateral reach to determine the within-day inter-rater reliability, and one tester repeated the measurement on day 2 to determine the intra-rater reliability between days. The leg lateral reach test was performed three times per leg, and the mean value was used for data analysis. Reliability was determined using the intraclass correlation coefficient, standard error of measurement, and minimal detectable change. The correlation between leg lateral reach distance and thoraco-lumbo-pelvic rotation range was determined using Pearson correlation.
RESULTS: Almost perfect intra- and inter-rater reliabilities were shown for the test [intraclass correlation coefficient2,3=0.97 (95% confidence interval=0.914-0.984) and 0.99 (0.974-0.996), respectively]. The within-day inter-rater standard error of measurement was 1.40cm, and the minimal detectable change was 3.87cm. The between-day intra-rater standard error of measurement was 2.66cm, and the minimal detectable change was 7.37cm. The Pearson correlation showed a moderate to good correlation between the leg lateral reach distance and the thoraco-lumbo-pelvic rotation range (r=0.73).
CONCLUSIONS: The leg lateral reach screening test is reliable for measuring thoraco-lumbo-pelvic rotation range and allows for practical measurement of the thoraco-lumbo-pelvic rotation range in a supine position.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app