Reliability of levator scapulae index in subjects with and without scapular downward rotation syndrome.
Physical Therapy in Sport 2016 May
OBJECTIVES: The objective of this study was to introduce levator scapulae (LS) measurement using a caliper and the levator scapulae index (LSI) and to investigate intra- and interrater reliability of the LSI in subjects with and without scapular downward rotation syndrome (SDRS).
DESIGN: Two raters measured LS length twice in 38 subjects (19 with SDRS and 19 without SDRS).
MAIN OUTCOME MEASURES: For reliability testing, intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.
RESULTS: Intrarater reliability analysis resulted with ICCs ranging from 0.94 to 0.98 in subjects with SDRS and 0.96 to 0.98 in subjects without SDRS. These results represented that intrarater reliability in both groups were excellent for measuring LS length with the LSI. Interrater reliability was good (ICC: 0.82) in subjects with SDRS; however, interrater reliability was moderate (ICC: 0.75) in subjects without SDRS. Additionally, SEM and MDC were 0.13% and 0.36% in subjects with SDRS and 0.35% and 0.97% in subjects without SDRS. In subjects with SDRS, low dispersion of the measurement errors and MDC were shown.
CONCLUSIONS: This study suggested that the LSI is a reliable method to measure LS length and is more reliable for subjects with SDRS.
DESIGN: Two raters measured LS length twice in 38 subjects (19 with SDRS and 19 without SDRS).
MAIN OUTCOME MEASURES: For reliability testing, intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.
RESULTS: Intrarater reliability analysis resulted with ICCs ranging from 0.94 to 0.98 in subjects with SDRS and 0.96 to 0.98 in subjects without SDRS. These results represented that intrarater reliability in both groups were excellent for measuring LS length with the LSI. Interrater reliability was good (ICC: 0.82) in subjects with SDRS; however, interrater reliability was moderate (ICC: 0.75) in subjects without SDRS. Additionally, SEM and MDC were 0.13% and 0.36% in subjects with SDRS and 0.35% and 0.97% in subjects without SDRS. In subjects with SDRS, low dispersion of the measurement errors and MDC were shown.
CONCLUSIONS: This study suggested that the LSI is a reliable method to measure LS length and is more reliable for subjects with SDRS.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app