Spectral-domain Optical Coherence Tomography Retinal and Choroidal Thickness Metric Repeatability in Age-related Macular Degeneration.

PURPOSE: To determine the intrasession repeatability of spectral-domain OCT (SDOCT)-derived macular retinal and choroidal metrics in patients with neovascular age-related macular degeneration (nAMD) in the Distance of Choroid Study (DOCS).

DESIGN: Validity and reliability analysis.

METHODS: Enrolled patients underwent repeated SDOCT imaging using the Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). A single technician certified for clinical trials took 3 macular volume scans. Retinal thicknesses were calculated for each of the 9 Early Treatment Diabetic Retinopathy Study (ETDRS) macular subfields. Center point thickness and total macular volume were also included in the analysis. Manual subfoveal choroidal thickness measurements were made by a masked observer.

RESULTS: A total of 40 eyes of 40 patients were included in this analysis (mean [± standard deviation] age: 74.1 [± 7.2] years, 60% male). The coefficient of repeatability (CR) of the central macular subfield was 30.6 μm (95% confidence interval [CI] 29.8-1.4 μm). The CR for the other macular subfields ranged from 7.0 μm to 38.2 μm. The CR for the total macular volume was 0.212 mm(3) (95% CI 0.206-0.217 mm(3)) and the CR for the center point was 47.5 μm (95% CI 46.2-48.7 μm). Images were also reviewed for the presence of segmentation error in the central macular subfield, and after exclusion of these eyes the revised CR for this subfield was 13.7 μm (95% CI 13.3-14.1 μm). The intrasession CR of subfoveal choroidal thickness was 34.7 μm (95% CI 33.7-35.7 μm).

CONCLUSIONS: This study suggests that a change of greater than 31 μm in Spectralis SDOCT-derived retinal thickness measurement of the central macular subfield and 35 μm in subfoveal choroidal thickness is necessary to detect true clinical change associated with disease progression or improvement in nAMD with a revised figure of 14 μm for central macular retinal subfield thickness in the absence of segmentation error.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app