Measuring mammographic density: comparing a fully automated volumetric assessment versus European radiologists' qualitative classification

Hanna Sartor, Kristina Lång, Aldana Rosso, Signe Borgquist, Sophia Zackrisson, Pontus Timberg
European Radiology 2016, 26 (12): 4354-4360
27011371

OBJECTIVES: Breast Imaging-Reporting and Data System (BI-RADS) mammographic density categories are associated with considerable interobserver variability. Automated methods of measuring volumetric breast density may reduce variability and be valuable in risk and mammographic screening stratification. Our objective was to assess agreement of mammographic density by a volumetric method with the radiologists' classification.

METHODS: Eight thousand seven hundred and eighty-two examinations from the Malmö Breast Tomosynthesis Screening Trial were classified according to BI-RADS, 4th Edition. Volumetric breast density was assessed using automated software for 8433 examinations. Agreement between volumetric breast density and BI-RADS was descriptively analyzed. Agreement between radiologists and between categorical volumetric density and BI-RADS was calculated, rendering kappa values.

RESULTS: The observed agreement between BI-RADS scores of different radiologists was 80.9 % [kappa 0.77 (0.76-0.79)]. A spread of volumetric breast density for each BI-RADS category was seen. The observed agreement between categorical volumetric density and BI-RADS scores was 57.1 % [kappa 0.55 (0.53-0.56)].

CONCLUSIONS: There was moderate agreement between volumetric density and BI-RADS scores from European radiologists indicating that radiologists evaluate mammographic density differently than software. The automated method may be a robust and valuable tool; however, differences in interpretation between radiologists and software require further investigation.

KEY POINTS: • Agreement between qualitative and software density measurements has not been frequently studied. • There was substantial agreement between different radiologists´ qualitative density assessments. • There was moderate agreement between software and radiologists' density assessments. • Differences in interpretation between software and radiologists require further investigation.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
27011371
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"