We have located links that may give you full text access.
Infant Parenteral Nutrition Remains a Significant Source for Aluminum Toxicity.
JPEN. Journal of Parenteral and Enteral Nutrition 2017 September
BACKGROUND: Aluminum toxicity is associated with anemia, impaired bone metabolism, neurologic defects, and parenteral nutrition (PN)-associated liver disease. This element is a ubiquitous contaminant of PN components, especially in infant formulations. We assessed the current levels of aluminum contamination in infant PN at a level III neonatal intensive care unit.
MATERIALS AND METHODS: Thirty samples of PN prepared in the same hospital for infants aged <30 days (mean [SD] weight, 1.54 [0.71] kg) were collected from discarded solution. Each sample was analyzed for aluminum content via inductively coupled plasma mass spectrometry. The components of PN (from label) and measured aluminum content were then compared using linear regression and 1-way analysis of variance.
RESULTS: The mean (SD) aluminum contamination of infant PN was 14.02 (6.51) mcg/kg/d. Only 3 samples were <5 mcg/kg/d. Aluminum levels and infant weight were not associated. Linear regression revealed a significant correlation between aluminum and both calcium gluconate ( P < .0001) and phosphate ( P = .05), with a trend between aluminum and potassium ( P = .07).
CONCLUSIONS: Aluminum contamination in infant PN remains almost 3 times higher than the advised maximum exposure (<5 mcg/kg/d, Food and Drug Administration 2004). Unexpectedly, an association between infant weight and aluminum exposure was not apparent, likely due to the homogeneity of our population. Isolating the source of aluminum contamination is difficult, as multiple components appear to be involved. Calcium gluconate is likely still a major contributor, but further investigations into individual components are warranted to promote the reduction of aluminum in infant PN.
MATERIALS AND METHODS: Thirty samples of PN prepared in the same hospital for infants aged <30 days (mean [SD] weight, 1.54 [0.71] kg) were collected from discarded solution. Each sample was analyzed for aluminum content via inductively coupled plasma mass spectrometry. The components of PN (from label) and measured aluminum content were then compared using linear regression and 1-way analysis of variance.
RESULTS: The mean (SD) aluminum contamination of infant PN was 14.02 (6.51) mcg/kg/d. Only 3 samples were <5 mcg/kg/d. Aluminum levels and infant weight were not associated. Linear regression revealed a significant correlation between aluminum and both calcium gluconate ( P < .0001) and phosphate ( P = .05), with a trend between aluminum and potassium ( P = .07).
CONCLUSIONS: Aluminum contamination in infant PN remains almost 3 times higher than the advised maximum exposure (<5 mcg/kg/d, Food and Drug Administration 2004). Unexpectedly, an association between infant weight and aluminum exposure was not apparent, likely due to the homogeneity of our population. Isolating the source of aluminum contamination is difficult, as multiple components appear to be involved. Calcium gluconate is likely still a major contributor, but further investigations into individual components are warranted to promote the reduction of aluminum in infant PN.
Full text links
Trending Papers
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2023 November 31
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app