Four-corner fusion: comparison of patient satisfaction and functional outcome of conventional K-wire technique vs. a new locking plate.
Archives of Orthopaedic and Trauma Surgery 2016 April
BACKGROUND: Four-corner fusion is a standard procedure for advanced carpal collapse. Several operative techniques and numerous implants for osseous fixation have been described. Recently, a specially designed locking plate (Aptus©, Medartis, Basel, Switzerland) was introduced. The purpose of this study was to compare functional results after osseous fixation using K-wires (standard of care, SOC) with four-corner fusion and locking plate fixation.
METHODS: 21 patients who underwent four-corner fusion in our institution between 2008 and 2013 were included in a retrospective analysis. In 11 patients, osseous fixation was performed using locking plates whereas ten patients underwent bone fixation with conventional K-wires. Outcome parameters were functional outcome, osseous consolidation, patient satisfaction (DASH- and Krimmer Score), pain and perioperative morbidity and the time until patients returned to daily work. Patients were divided in two groups and paired t-tests were performed for statistical analysis.
RESULTS: No implant related complications were observed. Osseous consolidation was achieved in all cases. Differences between groups were not significant regarding active range of motion (AROM), pain and function. Overall patient satisfaction was acceptable in all cases; differences in the DASH questionnaire and the Krimmer questionnaire were not significant. One patient of the plate group required conversion to total wrist arthrodesis without implant-related complications.
CONCLUSION: Both techniques for four-corner fusion have similar healing rates. Using the more expensive locking implant avoids a second operation for K-wire removal, but no statistical differences were detected in functional outcome as well as in patient satisfaction when compared to SOC.
METHODS: 21 patients who underwent four-corner fusion in our institution between 2008 and 2013 were included in a retrospective analysis. In 11 patients, osseous fixation was performed using locking plates whereas ten patients underwent bone fixation with conventional K-wires. Outcome parameters were functional outcome, osseous consolidation, patient satisfaction (DASH- and Krimmer Score), pain and perioperative morbidity and the time until patients returned to daily work. Patients were divided in two groups and paired t-tests were performed for statistical analysis.
RESULTS: No implant related complications were observed. Osseous consolidation was achieved in all cases. Differences between groups were not significant regarding active range of motion (AROM), pain and function. Overall patient satisfaction was acceptable in all cases; differences in the DASH questionnaire and the Krimmer questionnaire were not significant. One patient of the plate group required conversion to total wrist arthrodesis without implant-related complications.
CONCLUSION: Both techniques for four-corner fusion have similar healing rates. Using the more expensive locking implant avoids a second operation for K-wire removal, but no statistical differences were detected in functional outcome as well as in patient satisfaction when compared to SOC.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app