Add like
Add dislike
Add to saved papers

Correlation Between Corneal Button Size and Intraocular Pressure During Femtosecond Laser-Assisted Keratoplasty.

Cornea 2016 March
PURPOSE: To evaluate changes in intraocular pressure (IOP) in recipient and donor eyes during femtosecond laser-assisted keratoplasty (FLAK) and to assess for differences in the diameter of trephinated corneal buttons according to changes in pressure.

MATERIALS AND METHODS: Twenty porcine whole eyes (recipient model) and 20 porcine-corneoscleral rims (donor model) were prepared, and anterior chamber pressures were measured using a fiberoptic sensing device (Opsens, Quebec, Canada) during the femtosecond laser corneal cutting process. To determine the diameter of corneal buttons, 10 porcine whole eyes (recipient model) and 12 corneoscleral rims (donor model) of each baseline IOP were cut with the femtosecond laser programmed to the following pattern: "vertical side cut"; 1200 μm (depth), 8 mm (diameter). Digital photographs were obtained using microscopy and subsequently analyzed.

RESULTS: The IOP (mean ± SD) for the recipient model was 10.2 (±0.9) mm Hg at baseline and ranged from 96.6 (±4.5) to ∼138.4 (±3.8) mm Hg during the corneal cutting process. This shows that the maximum IOP during FLAK increased 13.5 times compared with baseline. In the donor model, the mean pressure elevation from baseline artificial anterior chamber (AAC) pressure to corneal cutting was 15.8 (±5.4) mm Hg. This showed a positive correlation with baseline IOP [correlation coefficient (CC) = 0.827, P = 0.006]. As the baseline IOP in the recipient eye increased, trephinated corneal button size was reduced by up to 3.9% in diameter (CC = -0.945, P = 0.015). In addition, in donor eyes, the diameter was decreased by up to 11.7% as the baseline AAC pressure increased (CC = -0.934, P = 0.006).

CONCLUSIONS: During the FLAK procedure, the IOP increases in both recipient and donor eyes. The diameter of the trephinated donor and recipient corneal buttons was decreased as the initial baseline IOP increased. Ophthalmic surgeons can determine the AAC pressure based on the baseline IOP in the recipient patient.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app