JOURNAL ARTICLE
META-ANALYSIS
REVIEW
SYSTEMATIC REVIEW
Add like
Add dislike
Add to saved papers

A systematic review and meta-analysis of the diagnostic accuracy of MRI for suspected ACL and meniscal tears of the knee.

PURPOSE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) and ultrasound (US) in the diagnosis of anterior cruciate ligament (ACL), medial meniscus and lateral meniscus tears in people with suspected ACL and/or meniscal tears.

METHODS: MEDLINE, Web of Science and the Cochrane library were searched from inception to March 2014. All prospective studies of the diagnostic accuracy of MRI or US against arthroscopy as the reference standard were included in the systematic review. Studies with a retrospective design and those with evidence of verification bias were excluded. Methodological quality of included studies was assessed using the QUADAS-2 tool. A meta-analysis of studies evaluating MRI to calculate the pooled sensitivity and specificity for each target condition was performed using a bivariate model with random effects. Sub-group and sensitivity analysis were used to examine the effect of methodological and other study variables.

RESULTS: There were 14 studies included in the meta-analysis of the accuracy of MRI for ACL tears, 19 studies included for medial meniscal tears and 19 studies for lateral meniscal tears. The summary estimates of sensitivity and specificity of MRI were 87 % (95 % CI 77-94 %) and 93 % (95 % CI 91-96 %), respectively, for ACL tears; 89 % (95 % CI 83-94 %) and 88 % (95 % CI 82-93 %), respectively, for medial meniscal tears; and 78 % (95 % CI 66-87 %) and 95 % (95 % CI 91-97 %), respectively, for lateral meniscal tears. Magnetic field strength had no significant effect on accuracy. Most studies had a high or unclear risk of bias. There were an insufficient number of studies that evaluated US to perform a meta-analysis.

CONCLUSION: This study provides a systematic review and meta-analysis of diagnostic accuracy studies of MRI and applies strict exclusion criteria in relation to the risk of verification bias. The risk of bias in most studies is high or unclear in relation to the reference standard. Concerns regarding the applicability of patient selection are also present in most studies.

LEVEL OF EVIDENCE: III.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app