Rapid and Accurate MRI Segmentation of Peritumoral Brain Edema in Meningiomas.
Clinical Neuroradiology 2017 June
PURPOSE: The extent of peritumoral brain edema (PTBE) in meningiomas commonly affects the clinical outcome. Despite its importance, edema volume is usually highly inaccurately approximated to a spheroid shape. We tested the accuracy and the reproducibility of semiautomatic lesion management software for the analysis of PTBE in a homogeneous case series of surgically confirmed intracranial meningiomas.
METHODS: PTBE volume was calculated on magnetic resonance images in 50 patients with intracranial meningiomas using commercial lesion management software (Vue PACS Livewire, Carestream, Rochester, NY, USA). Inter and intraobserver agreement evaluation and a comparison between manual volume calculation, the semiautomatic software and spheroid approximation were performed in 22 randomly selected patients.
RESULTS: The calculation of edema volume was possible in all cases irrespective of the extent of the signal changes. The median time for each calculation was 3 min. Interobserver and intraobserver agreement confirmed the reproducibility of the method. Comparison with standard (fully manual) calculation confirmed the accuracy of this software.
CONCLUSIONS: Our study showed a high level of reproducibility of this semiautomatic computational method for peritumoral brain edema. It is rapid and easy to use after relatively short training and is suitable for implementation in clinical practice.
METHODS: PTBE volume was calculated on magnetic resonance images in 50 patients with intracranial meningiomas using commercial lesion management software (Vue PACS Livewire, Carestream, Rochester, NY, USA). Inter and intraobserver agreement evaluation and a comparison between manual volume calculation, the semiautomatic software and spheroid approximation were performed in 22 randomly selected patients.
RESULTS: The calculation of edema volume was possible in all cases irrespective of the extent of the signal changes. The median time for each calculation was 3 min. Interobserver and intraobserver agreement confirmed the reproducibility of the method. Comparison with standard (fully manual) calculation confirmed the accuracy of this software.
CONCLUSIONS: Our study showed a high level of reproducibility of this semiautomatic computational method for peritumoral brain edema. It is rapid and easy to use after relatively short training and is suitable for implementation in clinical practice.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app