We have located links that may give you full text access.
JOURNAL ARTICLE
VALIDATION STUDIES
Analysis of 27 antibiotic residues in raw cow's milk and milk-based products--validation of Delvotest® T.
Food Additives & Contaminants. Part A, Chemistry, Analysis, Control, Exposure & Risk Assessment 2016
Delvotest® T was evaluated for its capability at detecting residues of 27 antibiotics in raw cow's milk and in some dairy ingredients (skimmed and full-cream milk powders). The kit was used as a screening tool for the qualitative determination of antibiotics from different families in a single test. Results delivered by such a method are expressed as 'positive' or 'negative', referring to the claimed screening target concentration (STC). Validation was conducted according to the European Community Reference Laboratories' (CRLs) residues guidelines of 20 January 2010 and performed by two laboratories, one located in Europe and the other in Asia. Five criteria were evaluated including detection capability at STC, false-positive (FP) rate, false-negative (FN) rate, robustness and cross-reactivity using visual reading and Delvoscan®. STCs were set at or below the corresponding maximum residue limit (MRL), as fixed by European Regulation EC No. 37/2010. Four antibiotics (nafcillin, oxytetracycline, tetracycline and rifaximin) out of 27 had a false-negative rate ranging from 1.7% to 4.9%; however, it was still compliant with the CRLs' requirements. Globally, Delvotest T can be recommended for the analysis of the surveyed antibiotics in raw cow's milk, skimmed and full-cream milk powders. Additional compounds were tested such as sulfamethazine, spiramycin and erythromycin; however, detection at the corresponding MRL was not achievable and these compounds were removed from the validation. Other drugs from the sulfonamide, aminoglycoside or macrolide families not detected by the test at the MRL were not evaluated in this study. Regarding the reliability of this rapid test to milk-based preparations, additional experiments should be performed on a larger range of compounds and samples to validate the Delvotest T in such matrices.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app