Inferior vena cava collapsibility loses correlation with internal jugular vein collapsibility during increased thoracic or intra-abdominal pressure.

Journal of Ultrasound 2015 December
PURPOSE: Point-of-care ultrasound evaluates inferior vena cava (IVC) and internal jugular vein (IJV) measurements to estimate intravascular volume status. The reliability of the IVC and IJV collapsibility index during increased thoracic or intra-abdominal pressure remains unclear.

METHODS: Three phases of sonographic scanning were performed: spontaneous breathing phase, increased thoracic pressure phase via positive pressure ventilation (PPV) phase, and increased intra-abdominal pressure (IAP) phase via laparoscopic insufflation to 15 mmHg. IVC measurements were done at 1-2 cm below the diaphragm and IJV measurements were done at the level of the cricoid cartilage during a complete respiratory cycle. Collapsibility index was calculated by (max diameter - min diameter)/max diameter × 100 %. Chi square, t test, correlation procedure (CORR) and Fisher's exact analyses were completed.

RESULTS: A total of 144 scans of the IVC and IJV were completed in 16 patients who underwent laparoscopic surgery. Mean age was 46 ± 15 years, with 75 % female and 69 % African-American. IVC and IJV collapsibility correlated in the setting of spontaneous breathing (r (2) = 0.86, p < 0.01). IVC collapsibility had no correlation with the IJV in the setting of PPV (r (2) = 0.21, p = 0.52) or IAP (r (2) = 0.26, p = 0.42). Maximal IVC diameter was significantly smaller during increased IAP (16.5 mm ± 4.9) compared to spontaneous breathing (20.6 mm ± 4.8, p = 0.04) and PPV (21.8 mm ± 5.6, p = 0.01).

CONCLUSION: IJV and IVC collapsibility correlated during spontaneous breathing but there was no statistically significant correlation during increased thoracic or intra-abdominal pressure. Increased intra-abdominal pressure was associated with a significant smaller maximal IVC diameter and cautions the reliability of IVC diameter in clinical settings that are associated with intra-abdominal hypertension or abdominal compartment syndrome.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app