JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

Diagnostic accuracy of loop-mediated isothermal amplification in detection of Clostridium difficile in stool samples: a meta-analysis.

INTRODUCTION: Clostridium difficile infection (CDI) remains a diagnostic challenge for clinicians. More recently, loop-mediated isothermal amplification (LAMP) has become readily available for the diagnosis of CDI, and many studies have investigated the usefulness of LAMP for rapid and accurate diagnosis of CDI. However, the overall diagnostic accuracy of LAMP for CDI remains unclear. In this meta-analysis, our aim was to establish the overall diagnostic accuracy of LAMP in detection of Clostridium difficile (CD) in stool samples.

MATERIAL AND METHODS: A search was done in PubMed, MEDLINE, EMBASE and Cochrane Library databases up to February 2014 to identify published studies that evaluated the diagnostic role of LAMP for CD. Methodological quality was assessed according to the quality assessment for studies of diagnostic accuracy (QUADAS) instrument. The sensitivities (SEN), specificities (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were pooled statistically using random effects models. Statistical analysis was performed by employing Meta-Disc 1.4 software. Summary receiver operating characteristic (SROC) curves were used to summarize overall test performance. Funnel plots were used to test the potential publication bias.

RESULT: A total of 9 studies met inclusion criteria for the present meta-analysis. The pooled SEN and SPE for diagnosing CD were 0.93 (95% CI: 0.91-0.95) and 0.98 (95% CI: 0.98-0.99), respectively. The PLR was 47.72 (95% CI: 15.10-150.82), NLR was 0.07 (95% CI: 0.04-0.14) and DOR was 745.19 (95% CI: 229.30-2421.72). The area under the ROC was 0.98. Meta-regression indicated that the total number of samples was a source of heterogeneity for LAMP in detection of CD. The funnel plots suggested no publication bias.

CONCLUSIONS: The LAMP meets the minimum desirable characteristics of a diagnostic test of SEN, SPE and other measures of accuracy in the diagnosis of CD, and it is suitable as a rapid, effective and reliable stand-alone diagnostic test for diagnosis of CDI, potentially decreasing morbidity and nosocomial spread of CD.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app