We have located links that may give you full text access.
Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer.
Physica Medica : PM 2015 December
PURPOSE: The purpose of this work is to compare the positioning accuracy achieved by three different imaging techniques and planar vs. CBCT imaging for two common IGRT indications.
METHODS: A collective of prostate cancer and head-and-neck cancer patients treated at our institution during the year 2013 was retrospectively analyzed. For all treatment fractions (3078 in total), the kind of acquired set-up image and the performed couch shift before treatment were assessed. The distribution of couch corrections was compared for three different imaging systems available at our institution: the treatment beam line operating at 6 MV, a dedicated imaging beam line of nominally 1 MV, and the kVision system at 70-121 kV. Shifts were analyzed for planar and cone-beam CT images. Based on the set-up corrections, CTV to PTV expansion margins were calculated.
RESULTS: The difference in set-up corrections performed for the three energies and both techniques (planar vs. CBCT) was not significant for head-and-neck cancer patients. For prostate cancer all shifts had equal variance. Averages ranged from -0.7 to +0.7 mm. The set-up margins calculated on the basis of the observed shifts are 4.0 mm (AP) and 3.8 mm (SI, LR) for the head-and-neck PTV and 6.6 mm (SI), 6.7 mm (AP) and 7.9 mm (LR) for the prostate cancer patients.
CONCLUSIONS: For three different linac-based imaging energies and planar/CBCT imaging, no relevant differences in set-up shifts were observed. The suggested set-up margins for these indications are of the order of 4 mm for head-and-neck and 6-8 mm for prostate treatment.
METHODS: A collective of prostate cancer and head-and-neck cancer patients treated at our institution during the year 2013 was retrospectively analyzed. For all treatment fractions (3078 in total), the kind of acquired set-up image and the performed couch shift before treatment were assessed. The distribution of couch corrections was compared for three different imaging systems available at our institution: the treatment beam line operating at 6 MV, a dedicated imaging beam line of nominally 1 MV, and the kVision system at 70-121 kV. Shifts were analyzed for planar and cone-beam CT images. Based on the set-up corrections, CTV to PTV expansion margins were calculated.
RESULTS: The difference in set-up corrections performed for the three energies and both techniques (planar vs. CBCT) was not significant for head-and-neck cancer patients. For prostate cancer all shifts had equal variance. Averages ranged from -0.7 to +0.7 mm. The set-up margins calculated on the basis of the observed shifts are 4.0 mm (AP) and 3.8 mm (SI, LR) for the head-and-neck PTV and 6.6 mm (SI), 6.7 mm (AP) and 7.9 mm (LR) for the prostate cancer patients.
CONCLUSIONS: For three different linac-based imaging energies and planar/CBCT imaging, no relevant differences in set-up shifts were observed. The suggested set-up margins for these indications are of the order of 4 mm for head-and-neck and 6-8 mm for prostate treatment.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university