Use of routine thoracic and abdominal computed tomography scans for assessing bone mineral density and detecting osteoporosis.

OBJECTIVE: Evaluation of computed tomography (CT) attenuation measurements for assessing bone mineral density (BMD) and predicting osteoporosis in thoracic and abdominal CT scans for various clinical indications using dual-energy X-ray absorptiometry (DXA) as reference standard.

RESEARCH DESIGN AND METHODS: A total of 234 patients (147 women, 87 men) undergoing DXA and CT were examined retrospectively. Mean time between both studies was 0.5 years. CT-attenuation values in Hounsfield units (HU) were measured at the thoracic and lumbar spine (T1, T6, T12, L1-L5), at the femoral neck, and then assigned to their corresponding DXA scores.

RESULTS: Patients with DXA-defined osteoporosis or osteopenia showed significantly lower HU values of trabecular bone at all measured levels compared to healthy subjects (p < 0.001). HU values were highest at T1 and T6, lowest at L1-L3 and the femoral neck. There were no significant intraindividual differences between HU values in the sagittal, coronal or transversal plane. Significant differences between normal and abnormal BMD categories were verified for three CT scanners. More than half of all fractures were detected in patients with non-osteoporotic DXA T-scores.

CONCLUSIONS: Abdominal and particularly thoracic CT scans obtained for other clinical indications can sensibly be applied toward determining low BMD, detecting osteoporosis and identifying persons at increased fracture risk. Osteoporotic morbidity and mortality might be minimized. Superiorly to DXA, fragility fractures can be found without additional imaging or radiation exposure which can initiate early adequate treatment.

LIMITATIONS: Key limitations of the study were as following: a retrospective, single-center study; small patient cohort - larger cohorts are needed to evaluate the sensitivity and specificity of diagnostic performance measurements; more complex CT evaluation of the hip for BMD assessment; DXA measurements were used as a reference standard, however, patients with unsuspected compression fractures but showing osteopenic or even normal BMD outline the limitations of DXA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app