We have located links that may give you full text access.
COMPARATIVE STUDY
ENGLISH ABSTRACT
JOURNAL ARTICLE
[Comparison of five video laryngoscopes and conventional direct laryngoscopy : Investigations on simple and simulated difficult airways on the intubation trainer].
Der Anaesthesist 2015 July
INTRODUCTION: Securing the airway with a tracheal tube is essential in emergency situations, in the intensive care setting as well as during anesthesia for surgery and other interventions. Current methods of airway assessment are poor screening tests for predicting difficult direct laryngoscopy due to a generally low positive predictive value; therefore, successful endotracheal intubation requires a high level of expertise, regular training and practice and sometimes additional tools. Currently, several video laryngoscopes (VL) with different designs are commercially available and have been investigated in a wide variety of settings. To our knowledge there is no prospective study evaluating and comparing performance among these three groups of VL; therefore, the aim of this study was to compare performance of five VL and conventional direct laryngoscopy in an intubation manikin model, both in a normal and simulated difficult intubation setting.
METHODS: In this study 10 residents, 12 senior staff physicians and 5 anesthesia nurses, all experienced in conventional direct laryngoscopy and inexperienced with VL underwent theoretical and hands-on training with all VL lasting 60 min. Afterwards participants performed intubation with all 5 VL and conventional direct laryngoscopy in a randomized sequence using an intubation manikin with normal intubation settings. Thereafter participants performed intubation in a simulated difficult intubation setting using the same intubation manikin with a neck collar to immobilize the cervical spine. In this study, the C-MAC(®) with Macintosh blade size 3, GlideScope(®) size 3, McGrath(®) series 5, King Vision(®) and Airtraq(®) size 2 were used. Time to intubation served as primary outcome and time to glottis visualization, number of intubation attempts, success rate and subjective evaluation of difficulty served as secondary outcomes.
RESULTS: In the normal intubation setting, time to intubation ranged from 16.0 s (conventional direct laryngoscopy) to 34.3 s (McGrath). GlideScope and conventional direct laryngoscopy were successful in 100 % followed by C-MAC (96.7 %), Airtraq (88.9 %), King Vision (77.8 %) and McGrath VL (44.4 %). In the simulated difficult intubation setting, time to intubation ranged between 20.3 s (Airtraq) and 26.7 s (McGrath). Success rate with C-MAC was 100 %, followed by GlideScope (96.7 %), Airtraq (85.2 %), conventional direct laryngoscopy (85.2 %), King Vision (81.5 %) and McGrath VL (70.4 %).
CONCLUSION: In the manikin with normal intubation setting, conventional direct laryngoscopy using a Macintosh blade was convincing and superior to any VL used in this study. During simulated difficult intubation, a blade with video transmission, such as C-MAC and the GlideScope were superior compared to conventional direct laryngoscopy and any other VL tested.
METHODS: In this study 10 residents, 12 senior staff physicians and 5 anesthesia nurses, all experienced in conventional direct laryngoscopy and inexperienced with VL underwent theoretical and hands-on training with all VL lasting 60 min. Afterwards participants performed intubation with all 5 VL and conventional direct laryngoscopy in a randomized sequence using an intubation manikin with normal intubation settings. Thereafter participants performed intubation in a simulated difficult intubation setting using the same intubation manikin with a neck collar to immobilize the cervical spine. In this study, the C-MAC(®) with Macintosh blade size 3, GlideScope(®) size 3, McGrath(®) series 5, King Vision(®) and Airtraq(®) size 2 were used. Time to intubation served as primary outcome and time to glottis visualization, number of intubation attempts, success rate and subjective evaluation of difficulty served as secondary outcomes.
RESULTS: In the normal intubation setting, time to intubation ranged from 16.0 s (conventional direct laryngoscopy) to 34.3 s (McGrath). GlideScope and conventional direct laryngoscopy were successful in 100 % followed by C-MAC (96.7 %), Airtraq (88.9 %), King Vision (77.8 %) and McGrath VL (44.4 %). In the simulated difficult intubation setting, time to intubation ranged between 20.3 s (Airtraq) and 26.7 s (McGrath). Success rate with C-MAC was 100 %, followed by GlideScope (96.7 %), Airtraq (85.2 %), conventional direct laryngoscopy (85.2 %), King Vision (81.5 %) and McGrath VL (70.4 %).
CONCLUSION: In the manikin with normal intubation setting, conventional direct laryngoscopy using a Macintosh blade was convincing and superior to any VL used in this study. During simulated difficult intubation, a blade with video transmission, such as C-MAC and the GlideScope were superior compared to conventional direct laryngoscopy and any other VL tested.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app