Novasure impedance control system versus microwave endometrial ablation for the treatment of dysfunctional uterine bleeding: a double-blind, randomized controlled trial.
PURPOSE OF INVESTIGATION: To compare the efficacy and safety of two different second-generation ablation devices, Novasure impedance control system and microwave endometrial ablation (MEA), in cases of abnormal uterine bleeding (AUB).
MATERIALS AND METHODS: This is a randomized controlled trial that took place in a single Gynecological Department of a University Hospital. Sixty-six women with dysfunctional uterine bleeding (DUB), unresponsive to medical treatment, were included in the trial. The ratio of women allocated to bipolar radio-frequency ablation or MEA was 1:1. Follow-up assessments were carried out at three and 12 months post-ablation. The present main outcome measure was amenorrhea rates 12-months post-treatment.
RESULTS: The rate of amenorrhea at 12-months post-ablation was significantly higher in women treated by Novasure (25/33; 75.8%) as compared to those treated by MEA (8/33; 24.2%) (rate difference: +51.5%, 95% CI: +27.8 to +67.7).
CONCLUSION: In women with DUB, endometrial ablation with Novasure bipolar radiofrequency impedance-controlled system is associated with increased rates of amenorrhea at 12-months post-treatment as compared to the MEA method.
MATERIALS AND METHODS: This is a randomized controlled trial that took place in a single Gynecological Department of a University Hospital. Sixty-six women with dysfunctional uterine bleeding (DUB), unresponsive to medical treatment, were included in the trial. The ratio of women allocated to bipolar radio-frequency ablation or MEA was 1:1. Follow-up assessments were carried out at three and 12 months post-ablation. The present main outcome measure was amenorrhea rates 12-months post-treatment.
RESULTS: The rate of amenorrhea at 12-months post-ablation was significantly higher in women treated by Novasure (25/33; 75.8%) as compared to those treated by MEA (8/33; 24.2%) (rate difference: +51.5%, 95% CI: +27.8 to +67.7).
CONCLUSION: In women with DUB, endometrial ablation with Novasure bipolar radiofrequency impedance-controlled system is associated with increased rates of amenorrhea at 12-months post-treatment as compared to the MEA method.
Full text links
Trending Papers
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2023 November 31
ANCA-associated vasculitis - Treatment Standard.Nephrology, Dialysis, Transplantation 2023 November 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app