Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure.
American Journal of Emergency Medicine 2015 November
OBJECTIVES: Pulmonary edema is a common sign of heart failure and can be quantified by counting vertical artifacts (B-lines) on lung ultrasound (LUS). The primary aim of this study was to compare a pocket size ultrasound device to high-end ultrasound systems on the measured number of B-lines. We also compared the impact of different-length ultrasound clips on the measured number of B-lines.
METHODS AND RESULTS: We studied 21 hospitalized patients with heart failure (81% men; median age, 73; 71% Caucasian) who underwent concurrent 8- and 4-zone LUS using both a pocket ultrasound device and a high-end ultrasound system. For the 4-zone scanning method, the median B line number was 2 (interquartile range, 1-4) for the pocket device and 3 (1-5) for the high-end system (P = .67). For the 8-zone method, the median B-line number was 4 (2-7) for the pocket device and 5 (3-7) for the high-end system (P = .18). A higher number of B-lines was identified on the 4- vs 2-second LUS clips (P < .001 for 4 zones, P = .001 for 8 zones), and on the 6- vs 4-second LUS clips (P=0.057 for 4 zones, P=0.018 for 8 zones).
CONCLUSIONS: Our findings suggest significant differences based on LUS clip duration rather than the type of ultrasound device used, with respect to the number of B-lines detectable in patients with heart failure. These factors should be considered in the design and reporting of LUS studies and in longitudinal assessments of heart failure patients.
METHODS AND RESULTS: We studied 21 hospitalized patients with heart failure (81% men; median age, 73; 71% Caucasian) who underwent concurrent 8- and 4-zone LUS using both a pocket ultrasound device and a high-end ultrasound system. For the 4-zone scanning method, the median B line number was 2 (interquartile range, 1-4) for the pocket device and 3 (1-5) for the high-end system (P = .67). For the 8-zone method, the median B-line number was 4 (2-7) for the pocket device and 5 (3-7) for the high-end system (P = .18). A higher number of B-lines was identified on the 4- vs 2-second LUS clips (P < .001 for 4 zones, P = .001 for 8 zones), and on the 6- vs 4-second LUS clips (P=0.057 for 4 zones, P=0.018 for 8 zones).
CONCLUSIONS: Our findings suggest significant differences based on LUS clip duration rather than the type of ultrasound device used, with respect to the number of B-lines detectable in patients with heart failure. These factors should be considered in the design and reporting of LUS studies and in longitudinal assessments of heart failure patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app