Quantification of hearing loss in patients with posterior semicircular canal dehiscence.
CONCLUSION: Patients with posterior semicircular canal dehiscence (PSCD) have low frequency conductive hearing loss similar to patients with superior semicircular canal dehiscence (SSCD) secondary to a pathologic third window.
OBJECTIVES: PSCD can result in conductive hearing loss, but the magnitude of this hearing loss remains to be quantified. Patients with SSCD have been shown to have low frequency conductive hearing loss. The underlying pathophysiology of hearing loss from PSCD and SSCD is similar and related to a pathologic third window.
METHOD: A PubMed search was completed for a meta-analysis of patients with PSCD. Articles with quality audiograms were obtained. Air conduction thresholds for ears with posterior semicircular canal dehiscence were compared to the opposite ear as well as normal control data.
RESULTS: Eight articles with 21 patients with PSCD and quality audiograms were included. Two patients had bilateral PSCD and one of those was excluded because hearing thresholds were at the limit of the audiometer. Patients with posterior semicircular canal dehiscence have statistically significant lower air conduction thresholds in frequencies at and below 2000 Hz.
OBJECTIVES: PSCD can result in conductive hearing loss, but the magnitude of this hearing loss remains to be quantified. Patients with SSCD have been shown to have low frequency conductive hearing loss. The underlying pathophysiology of hearing loss from PSCD and SSCD is similar and related to a pathologic third window.
METHOD: A PubMed search was completed for a meta-analysis of patients with PSCD. Articles with quality audiograms were obtained. Air conduction thresholds for ears with posterior semicircular canal dehiscence were compared to the opposite ear as well as normal control data.
RESULTS: Eight articles with 21 patients with PSCD and quality audiograms were included. Two patients had bilateral PSCD and one of those was excluded because hearing thresholds were at the limit of the audiometer. Patients with posterior semicircular canal dehiscence have statistically significant lower air conduction thresholds in frequencies at and below 2000 Hz.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app