We have located links that may give you full text access.
Journal Article
Observational Study
Impact of a Two-step Emergency Department Triage Model with START, then CTAS, on Patient Flow During a Simulated Mass-casualty Incident.
Prehospital and Disaster Medicine 2015 August
INTRODUCTION: A high influx of patients during a mass-casualty incident (MCI) may disrupt patient flow in an already overcrowded emergency department (ED) that is functioning beyond its operating capacity. This pilot study examined the impact of a two-step ED triage model using Simple Triage and Rapid Treatment (START) for pre-triage, followed by triage with the Canadian Triage and Acuity Scale (CTAS), on patient flow during a MCI simulation exercise. Hypothesis/Problem It was hypothesized that there would be no difference in time intervals nor patient volumes at each patient-flow milestone.
METHODS: Physicians and nurses participated in a computer-based tabletop disaster simulation exercise. Physicians were randomized into the intervention group using START, then CTAS, or the control group using START alone. Patient-flow milestones including time intervals and patient volumes from ED arrival to triage, ED arrival to bed assignment, ED arrival to physician assessment, and ED arrival to disposition decision were compared. Triage accuracy was compared for secondary purposes.
RESULTS: There were no significant differences in the time interval from ED arrival to triage (mean difference 108 seconds; 95% CI, -353 to 596 seconds; P=1.0), ED arrival to bed assignment (mean difference 362 seconds; 95% CI, -1,269 to 545 seconds; P=1.0), ED arrival to physician assessment (mean difference 31 seconds; 95% CI, -1,104 to 348 seconds; P=0.92), and ED arrival to disposition decision (mean difference 175 seconds; 95% CI, -1,650 to 1,300 seconds; P=1.0) between the two groups. There were no significant differences in the volume of patients to be triaged (32% vs 34%; 95% CI for the difference -16% to 21%; P=1.0), assigned a bed (16% vs 21%; 95% CI for the difference -11% to 20%; P=1.0), assessed by a physician (20% vs 22%; 95% CI for the difference -14% to 19%; P=1.0), and with a disposition decision (20% vs 9%; 95% CI for the difference -25% to 4%; P=.34) between the two groups. The accuracy of triage was similar in both groups (57% vs 70%; 95% CI for the difference -15% to 41%; P=.46).
CONCLUSION: Experienced triage nurses were able to apply CTAS effectively during a MCI simulation exercise. A two-step ED triage model using START, then CTAS, had similar patient flow and triage accuracy when compared to START alone.
METHODS: Physicians and nurses participated in a computer-based tabletop disaster simulation exercise. Physicians were randomized into the intervention group using START, then CTAS, or the control group using START alone. Patient-flow milestones including time intervals and patient volumes from ED arrival to triage, ED arrival to bed assignment, ED arrival to physician assessment, and ED arrival to disposition decision were compared. Triage accuracy was compared for secondary purposes.
RESULTS: There were no significant differences in the time interval from ED arrival to triage (mean difference 108 seconds; 95% CI, -353 to 596 seconds; P=1.0), ED arrival to bed assignment (mean difference 362 seconds; 95% CI, -1,269 to 545 seconds; P=1.0), ED arrival to physician assessment (mean difference 31 seconds; 95% CI, -1,104 to 348 seconds; P=0.92), and ED arrival to disposition decision (mean difference 175 seconds; 95% CI, -1,650 to 1,300 seconds; P=1.0) between the two groups. There were no significant differences in the volume of patients to be triaged (32% vs 34%; 95% CI for the difference -16% to 21%; P=1.0), assigned a bed (16% vs 21%; 95% CI for the difference -11% to 20%; P=1.0), assessed by a physician (20% vs 22%; 95% CI for the difference -14% to 19%; P=1.0), and with a disposition decision (20% vs 9%; 95% CI for the difference -25% to 4%; P=.34) between the two groups. The accuracy of triage was similar in both groups (57% vs 70%; 95% CI for the difference -15% to 41%; P=.46).
CONCLUSION: Experienced triage nurses were able to apply CTAS effectively during a MCI simulation exercise. A two-step ED triage model using START, then CTAS, had similar patient flow and triage accuracy when compared to START alone.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university