Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis.

OBJECTIVES: In propensity score-matched patients with severe aortic stenosis treated with surgical aortic valve replacement (AVR) with the 3f Enable sutureless prosthesis (Medtronic, Minneapolis, Minnesota) or transcatheter aortic valve replacement (TAVR), the hemodynamic performance of both valves and mid-term survival of patients were evaluated.

BACKGROUND: Data on hemodynamic performance of surgical sutureless bioprostheses in high operative risk patients with aortic stenosis are scarce.

METHODS: Of 258 patients undergoing TAVR or surgical aortic valve replacement with the 3f Enable valve, 80 (79 ± 5 years of age, 100% men) were included in the current analysis on the basis of propensity score 1:1 matching for baseline clinical and hemodynamic characteristics. All patients had hemodynamic echocardiographic evaluation at baseline and discharge. Mid-term survival was analyzed.

RESULTS: Compared with the 3f Enable valve, TAVR prostheses (Edwards SAPIEN XT [Edwards Lifesciences, Irvine, California] and CoreValve [Medtronic]) had larger effective orifice area index (1.00 ± 0.30 cm(2)/m(2) vs. 0.76 ± 0.22 cm(2)/m(2); p < 0.001), lower pressure gradient (8.14 ± 4.21 mm Hg vs. 10.72 ± 4.01 mm Hg; p = 0.006), less frequent prosthesis-patient mismatch (30.0% vs. 67.5%; p = 0.001), and low flow (46.2% vs. 72.5%; p = 0.02), but more frequent aortic regurgitation (87.5% vs. 20.0%; p < 0.001). The presence of prosthesis-patient mismatch was independently associated with a low-flow state at discharge (odds ratio: 4.70; p = 0.004) and independently associated with the use of the sutureless prosthesis (odds ratio: 3.90; p = 0.02). However, the survival of the 2 groups was comparable after 1.5-year (interquartile range: 0.79 to 2.01 years) follow-up (log-rank test, p = 0.95).

CONCLUSIONS: TAVR prostheses demonstrated better hemodynamics than the 3f Enable valve but a higher incidence of aortic regurgitation. However, these differences did not influence mid-term survival of patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app