JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

Safety and Procedural Success of Left Atrial Appendage Exclusion With the Lariat Device: A Systematic Review of Published Reports and Analytic Review of the FDA MAUDE Database.

IMPORTANCE: The Lariat device has received US Food and Drug Administration (FDA) 510(k) clearance for soft-tissue approximation and is being widely used off-label for left atrial appendage (LAA) exclusion. A comprehensive analysis of safety and effectiveness has not been reported.

OBJECTIVES: To perform a systematic review of published literature to assess safety and procedural success, defined as successful closure of the LAA during the index procedure, of the Lariat device. We performed a formal analytic review of the FDA MAUDE (Manufacturer and User Facility Device Experience) database to compile adverse event reports from real-world practice with the Lariat.

DATA SOURCES: For the systematic review, PubMed, EMBASE, CINAHL, and the Cochrane Library were searched from January 2007 through August 2014 to identify all studies reporting use of the Lariat device in 3 or more patients. The FDA MAUDE database was queried for adverse events reports related to Lariat use.

DATA EXTRACTIONS AND SYNTHESIS: Data were abstracted in duplicate by 2 physician reviewers. Events from published literature were pooled using a generic inverse variance weighting with a random effects model. Cumulative and individual adverse events were also reported using the FDA MAUDE data set.

MAIN OUTCOMES AND MEASURES: Procedural adverse events and procedural success.

RESULTS: In the systematic review, 5 reports of Lariat device use in 309 participants were identified. Specific complications weighted for inverse of variance of individual studies were urgent need for cardiac surgery (2.3%; 7 of 309 procedures) and death (0.3%; 1 of 309 procedures). Procedural success was 90.3% (279 of 309 procedures). In the FDA MAUDE database, there were 35 unique reports of adverse events with use of the Lariat device. Among these, we identified 5 adverse event reports that noted pericardial effusion and death and an additional 23 reported urgent cardiac surgery without mention of death.

CONCLUSIONS AND RELEVANCE: This review of published reports and case reports identified risks of adverse events with off-label use of the Lariat device for LAA exclusion. Formal, controlled investigations into the safety and efficacy of the device for this indication are warranted.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app