COMPARATIVE STUDY
CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Detection of left atrial thrombus by intracardiac echocardiography in patients undergoing ablation of atrial fibrillation.

BACKGROUND: The role of intracardiac echocardiography (ICE) to detect thrombus within left atrium (LA) before atrial fibrillation (AF) ablation despite a recent transesophageal echocardiogram (TEE) is not well defined. We examined the prevalence of LA/left atrial appendage (LAA) thrombus using ICE immediately prior to AF ablation in patients in whom anticoagulation was not withheld.

METHODS: We analyzed 122 consecutive patients (62.6 ± 10.8 years, 90 males, CHA(2)DS(2) -VASc score 2.4 ± 1.5, persistent AF 29.5 %) who underwent an ICE-guided AF ablation 1 day after a negative (n = 120) or inconclusive (n = 2) TEE for LA thrombus. LA was imaged with ICE from the right atrium, coronary sinus, and right ventricular inflow tract (RVIT). ICE and TEE images were compared for LAA area, thrombus, and spontaneous echo contrast (SEC).

RESULTS: LAA was adequately visualized in 99 and 100 % of patients with TEE and ICE, respectively. RVIT was the best ICE view for LAA visualization. The LAA 2-D-area measured by TEE was 4.9 ± 0.5 vs. 5 ± 0.5 cm(2) by ICE (P = NS). ICE identified a thrombus in seven patients with a previous negative TEE, leading to cancellation of ablation. It ruled out a thrombus in two patients with an inconclusive TEE. Thrombi were found in the LAA (n = 4), atrial septum (n = 2), and left superior pulmonary vein (n = 1). SEC during TEE was more frequent in patients with thrombus on ICE than those without (85.7 vs. 17.4 %; p = 0.03; positive predictive value 23.1 %, negative predictive value 98.9 %).

CONCLUSIONS: The results of our staged imaging approach suggest that ICE has a complimentary value in re-screening the LA/LAA for thrombus after a recent negative or equivocal TEE. The presence of SEC during TEE increases the probability of finding a thrombus with ICE, which could potentially be dislodged during catheter manipulation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app