Long-term follow-up study of osteoporotic vertebral compression fracture treated using balloon kyphoplasty and vertebroplasty.

OBJECT: Long-term follow-up study is required for verifying whether the clinical outcomes of kyphoplasty and vertebroplasty are altered. The authors' findings showed only subtle differences between these operations within a 5-year period. However, they still suggest the use of vertebroplasty over kyphoplasty in view of the treatment costs. In their previous study, the authors performed a short-term prospective comparison between vertebroplasty and kyphoplasty. Vertebroplasty was recommended instead of kyphoplasty for the treatment of vertebral compression fractures (VCFs) because of the subtle differences between this procedure and kyphoplasty and the treatment costs. To determine whether these clinical outcomes persist in the long term, they continued to observe the patients from their short-term study over a longer-term period. METHODS :One hundred cases of VCF were assigned randomly to either the kyphoplasty or the vertebroplasty group. In cement augmentation, the authors used polymethylmethacrylate as bone filler. Pain was assessed by using a visual analog scale (VAS). For each patient, vertebral body height and wedge angle were measured from reconstructed CT images.

RESULTS: The duration of the follow-up period was 5 years. Vertebral body height, kyphotic wedge angle, and VAS score were not evidently altered. Eight patients in the kyphoplasty group had an adjacent fracture after the procedure, whereas 7 patients in the vertebroplasty group had an adjacent fracture after the procedure. These adjacent fractures occurred within 1 year of surgery in both treatment groups except in 1 kyphoplasty-treated patient in whom the adjacent fracture was noted 16 months after treatment. Three patients in the vertebroplasty group had a nonadjacent fracture, and 4 patients in the kyphoplasty group had a nonadjacent fracture. The link between angular correction and the occurrence of adjacent fracture was statistically significant in the vertebroplasty group.

CONCLUSIONS: Excessive angular correction is a critical concern in the risk of adjacent fracture after vertebroplasty. Given the subtle differences between vertebroplasty and kyphoplasty observed over the course of 5 years, vertebroplasty remains the preferred option in view of the costs.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app