Identification of location of nerve catheters using pumping maneuver and M-Mode-a novel technique.
Journal of Clinical Anesthesia 2015 June
BACKGROUND: Optimum positioning of the nerve catheter is crucial for a successful nerve block. We present a novel technique for confirmation of catheter position.
METHODS: We are describing a novel technique for localization of the shaft and tip of the peripheral nerve catheter. After introduction of the catheter 3 to 5 cm beyond the needle tip and removal of the needle, the guide wire was reintroduced and was moved inward and outward rapidly. This movement produced the color Doppler effect along the track of the catheter and the catheter tip that helped us verify the proper positioning of the catheter.
RESULTS: We used our technique in a cadaveric study for bilateral supraclavicular brachial plexus block, followed by a series of 5 patients undergoing femoral, sciatic (anterior approach), popliteal (2 patients), and brachial plexus blocks. Catheters were also identified on M-Mode sonography during pumping maneuver and during the injection of medications.
CONCLUSION: Pumping maneuver and M-Mode can be additional tools in the array of modalities applied to verify proper positioning of a nerve catheter.
METHODS: We are describing a novel technique for localization of the shaft and tip of the peripheral nerve catheter. After introduction of the catheter 3 to 5 cm beyond the needle tip and removal of the needle, the guide wire was reintroduced and was moved inward and outward rapidly. This movement produced the color Doppler effect along the track of the catheter and the catheter tip that helped us verify the proper positioning of the catheter.
RESULTS: We used our technique in a cadaveric study for bilateral supraclavicular brachial plexus block, followed by a series of 5 patients undergoing femoral, sciatic (anterior approach), popliteal (2 patients), and brachial plexus blocks. Catheters were also identified on M-Mode sonography during pumping maneuver and during the injection of medications.
CONCLUSION: Pumping maneuver and M-Mode can be additional tools in the array of modalities applied to verify proper positioning of a nerve catheter.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app