Add like
Add dislike
Add to saved papers

Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

OBJECTIVE: To assess the diagnostic quality of low dose (100 kV) CT angiography (CTA), by using ultra-low contrast medium volume (30 ml), for thoracic and abdominal aorta evaluation.

METHODS: 67 patients with thoracic or abdominal vascular disease underwent multidetector CT study using a 256 slice scanner, with low dose radiation protocol (automated tube current modulation, 100 kV) and low contrast medium volume (30 ml; 4 ml s(-1)). Density measurements were performed on ascending, arch, descending thoracic aorta, anonymous branch, abdominal aorta, and renal and common iliac arteries. Radiation dose exposure [dose-length product (DLP)] was calculated. A control group of 35 patients with thoracic or abdominal vascular disease were evaluated with standard CTA protocol (automated tube current modulation, 120 kV; contrast medium, 80 ml).

RESULTS: In all patients, we correctly visualized and evaluated main branches of the thoracic and abdominal aorta. No difference in density measurements was achieved between low tube voltage protocol (mean attenuation value of thoracic aorta, 304 HU; abdominal, 343 HU; renal arteries, 331 HU) and control group (mean attenuation value of thoracic aorta, 320 HU; abdominal, 339; renal arteries, 303 HU). Radiation dose exposure in low tube voltage protocol was significantly different between thoracic and abdominal low tube voltage studies (490 and 324 DLP, respectively) and the control group (thoracic DLP, 1032; abdomen, DLP 1078).

CONCLUSION: Low-tube-voltage protocol may provide a diagnostic performance comparable with that of the standard protocol, decreasing radiation dose exposure and contrast material volume amount.

ADVANCES IN KNOWLEDGE: Low-tube-voltage-setting protocol combined with ultra-low contrast agent volume (30 ml), by using new multidetector-row CT scanners, represents a feasible diagnostic tool to significantly reduce the radiation dose delivered to patients and to preserve renal function, while also maintaining adequate diagnostic quality images in assessment of aorta.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app