We have located links that may give you full text access.
Are first ventilatory threshold and 6-minute walk test heart rate interchangeable? A pilot study in healthy elderlies and cardiac patients.
BACKGROUND: Heart rate (HR) at the ventilatory threshold (VT) is often used to prescribe exercise intensity in cardiac rehabilitation. Some studies have reported no significant difference between HR at VT and HR measured at the end of a 6-min walk test (6-MWT) in cardiac patients. The aim of this work was to assess the potential equivalence between those parameters at the individual level.
METHOD: Three groups of subjects performed a stress test and a 6-MWT: 22 healthy elderlies (GES, 77 ± 3.7 years), 10 stable coronary artery disease (CAD) patients (GMI, 50.9 ± 4.2 years) and 30 patients with chronic heart failure (GHF, 63.3 ± 10 years). We analyzed the correlation, mean bias, 95% confidence interval (95% CI) of the mean bias and the magnitude of the bias between 6-MWT-HR and VT-HR.
RESULTS: There was a significant difference between 6-MWT and VT-HR in GHF (99.1 ± 8.8 vs 91.6 ± 18.6 bpm, P=0.016) but not in GES and GMI. The correlation between those 2 parameters was high for GMI (r=0.78, P<0.05), and moderate for GES and GHF (r=0.48 and 0.55, respectively, P<0.05). The 95% CI of bias was large (>30%) in GES and GHF and acceptable in GMI (8-12%).
CONCLUSION: 6-MWT-HR and VT-HR do not appear interchangeable at the individual level in healthy elderlies and CHF patients. In CAD patients, further larger studies and/or the development of other walk tests could help in confirming the interest of a training prescription based on walking performance, after an exhaustive study of their cardiometabolic requirements.
METHOD: Three groups of subjects performed a stress test and a 6-MWT: 22 healthy elderlies (GES, 77 ± 3.7 years), 10 stable coronary artery disease (CAD) patients (GMI, 50.9 ± 4.2 years) and 30 patients with chronic heart failure (GHF, 63.3 ± 10 years). We analyzed the correlation, mean bias, 95% confidence interval (95% CI) of the mean bias and the magnitude of the bias between 6-MWT-HR and VT-HR.
RESULTS: There was a significant difference between 6-MWT and VT-HR in GHF (99.1 ± 8.8 vs 91.6 ± 18.6 bpm, P=0.016) but not in GES and GMI. The correlation between those 2 parameters was high for GMI (r=0.78, P<0.05), and moderate for GES and GHF (r=0.48 and 0.55, respectively, P<0.05). The 95% CI of bias was large (>30%) in GES and GHF and acceptable in GMI (8-12%).
CONCLUSION: 6-MWT-HR and VT-HR do not appear interchangeable at the individual level in healthy elderlies and CHF patients. In CAD patients, further larger studies and/or the development of other walk tests could help in confirming the interest of a training prescription based on walking performance, after an exhaustive study of their cardiometabolic requirements.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app