Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization?

Alistair Kent, Prabhav Patil, Victor Davila, J Kevin Bailey, Christian Jones, David C Evans, Creagh T Boulger, Eric Adkins, Jayaraj M Balakrishnan, Sebastian Valiyaveedan, Sagar C Galwankar, David P Bahner, Stanislaw P Stawicki
Annals of Thoracic Medicine 2015, 10 (1): 44-9
25593607

INTRODUCTION: Inferior vena cava collapsibility index (IVC-CI) has been shown to correlate with both clinical and invasive assessment of intravascular volume status, but has important limitations such as the requirement for advanced sonographic skills, the degree of difficulty in obtaining those skills, and often challenging visualization of the IVC in the postoperative patient. The current study aims to explore the potential for using femoral (FV) or internal jugular (IJV) vein collapsibility as alternative sonographic options in the absence of adequate IVC visualization.

METHODS: A prospective, observational study comparing IVC-CI and Fem- and/or IJV-CI was performed in two intensive care units (ICU) between January 2012 and April 2014. Concurrent M-mode measurements of IVC-CI and FV- and/or IJV-CI were collected during each sonographic session. Measurements of IVC were obtained using standard technique. IJV-CI and FV-CI were measured using high-frequency, linear array ultrasound probe placed in the corresponding anatomic areas. Paired data were analyzed using coefficient of correlation/determination and Bland-Altman determination of measurement bias.

RESULTS: We performed paired ultrasound examination of IVC-IJV (n = 39) and IVC-FV (n = 22), in 40 patients (mean age 54.1; 40% women). Both FV-CI and IJV-CI scans took less time to complete than IVC-CI scans (both, P < 0.02). Correlations between IVC-CI/FV-CI (R(2) = 0.41) and IVC-CI/IJV-CI (R(2) = 0.38) were weak. There was a mean -3.5% measurement bias between IVC-CI and IJV-CI, with trend toward overestimation for IJV-CI with increasing collapsibility. In contrast, FV-CI underestimated collapsibility by approximately 3.8% across the measured collapsibility range.

CONCLUSION: Despite small measurement biases, correlations between IVC-CI and FV-/IJV-CI are weak. These results indicate that IJ-CI and FV-CI should not be used as a primary intravascular volume assessment tool for clinical decision support in the ICU. The authors propose that IJV-CI and FV-CI be reserved for clinical scenarios where sonographic acquisition of both IVC-CI or subclavian collapsibility are not feasible, especially when trended over time. Sonographers should be aware that IJV-CI tends to overestimate collapsibility when compared to IVC-CI, and FV-CI tends to underestimates collapsibility relative to IVC-CI.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
25593607
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"