We have located links that may give you full text access.
Journal Article
Observational Study
The bubble study: ultrasound confirmation of central venous catheter placement.
American Journal of Emergency Medicine 2015 March
STUDY OBJECTIVE: The objective was to determine if ultrasound (US) can more rapidly confirm central venous catheter (CVC) position in comparison to chest radiography (CXR) in the emergency department.
METHODS: The study included a convenience sample of emergency department patients with supradiaphragmatic CVCs and a CXR for confirmation. Ultrasound was used for CVC confirmation by visualizing microbubble artifact in the right atrium after injection of saline through the distal port. To evaluate for pneumothorax (PTX), "sliding sign" of the pleura was noted on US of the anterior chest. Blinded chart review was performed to assess CXR timing, catheter position and CVC complications. Student's t test was used to compare US time to CXR performance time and radiologist reading time.
RESULTS: Fifty patients were enrolled; 4 were excluded because of inadequate views. Forty-six patients were included in the final analysis. Mean total US time was 5.0 minutes (95% confidence interval [CI], 4.2-5.9) compared to 28.2 minutes (95% CI, 16.8-39.4) for CXR performance with a mean difference of 23.1 minutes (95% CI, -34.5 to -11.8; P < .0002). When comparing only US CVC confirmation time to CXR time, US was an average of 24.0 minutes (95% CI, -35.4 to -12.7; P < .0001) faster. Comparing total US time to radiologist CXR reading time, US was an average of 294 minutes faster (95% CI, -384.5 to -203.5; P < .0000). There were a total of 3 misplaced lines and 2 patients with PTX, all of which were identified correctly on US.
CONCLUSION: Ultrasound can confirm CVC placement and rule out PTX significantly faster than CXR, expediting the use of CVCs in the critically ill.
METHODS: The study included a convenience sample of emergency department patients with supradiaphragmatic CVCs and a CXR for confirmation. Ultrasound was used for CVC confirmation by visualizing microbubble artifact in the right atrium after injection of saline through the distal port. To evaluate for pneumothorax (PTX), "sliding sign" of the pleura was noted on US of the anterior chest. Blinded chart review was performed to assess CXR timing, catheter position and CVC complications. Student's t test was used to compare US time to CXR performance time and radiologist reading time.
RESULTS: Fifty patients were enrolled; 4 were excluded because of inadequate views. Forty-six patients were included in the final analysis. Mean total US time was 5.0 minutes (95% confidence interval [CI], 4.2-5.9) compared to 28.2 minutes (95% CI, 16.8-39.4) for CXR performance with a mean difference of 23.1 minutes (95% CI, -34.5 to -11.8; P < .0002). When comparing only US CVC confirmation time to CXR time, US was an average of 24.0 minutes (95% CI, -35.4 to -12.7; P < .0001) faster. Comparing total US time to radiologist CXR reading time, US was an average of 294 minutes faster (95% CI, -384.5 to -203.5; P < .0000). There were a total of 3 misplaced lines and 2 patients with PTX, all of which were identified correctly on US.
CONCLUSION: Ultrasound can confirm CVC placement and rule out PTX significantly faster than CXR, expediting the use of CVCs in the critically ill.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app