JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL

Low-concentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition

Minwen Zheng, Yongjie Wu, Mengqi Wei, Ying Liu, Hongliang Zhao, Jian Li
Academic Radiology 2015, 22 (2): 195-202
25457735

RATIONALE AND OBJECTIVES: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality, and radiation dose of coronary computed tomography (CT) angiography (CCTA) by using prospectively electrocardiography (ECG)-triggered high-pitch spiral acquisition with low tube voltage in combination with iterative reconstruction.

MATERIALS AND METHODS: One hundred patients (body mass index ≤ 25 kg/m(2), heart rate ≤ 65 beats per minute) were prospectively randomized to two groups, with 50 patients each, which were differed by contrast medium. All patients underwent prospectively ECG-triggered high-pitch spiral acquisition CCTA (2 × 128 × 0.6 mm, 300 mAs). Group A patients received iopromide 370 (370 mg I/mL), were scanned using 100 kVp, and reconstructed with filtered back projection. Group B patients received Iodixanol 270 (270 mg I/mL), were scanned using low tube voltage of 80 kVp, and reconstructed with iterative reconstruction techniques (IRT). CT attenuation was measured in coronary artery and other anatomic regions. Image quality score, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiation dose were calculated and compared.

RESULTS: The iodixanol 270 group showed no significant difference in image quality score (1.61 ± 0.69 vs 1.57 ± 0.66; P > .05), CT attenuation (P > .05), noise (P > .05), SNR (47.89 ± 14.03 vs 44.37 ± 12.79; P > .05), and CNR (42.38 ± 12.67 vs 38.13 ± 11.38; P > .05) in comparison to the iopromide 370 group but at a significantly lower radiation dose (0.26 ± 0.05 vs 0.57 ± 0.10; P < .001), which reflects dose saving of 54.4%.

CONCLUSIONS: Combining IRT with high-pitch spiral acquisition mode and low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/mL can still maintain the contrast enhancement in coronary arteries without impairing image quality and significantly lower the radiation dose.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
25457735
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"